3.6.2.3 NTC dryer heater (1)
The
NTC dryer heater
(3) controls the temperatures for the drying
programmes:
►
Cottons/Coloureds:
►
Easy care:
►
Excess temperature:
3.6.2.4 Safety temperature switch (3)
The
safety temperature switch
duct to 150 °C if the NTCD3 (1) is defective (characteristic shifted).
It can be manually reset.
815_58300000146136_ara_en_b.doc – 12.04.10
90 °C
70 °C
105 °C
limits the temperature in the heating
Seite 14 von 32