SLEEP FEATURE:
Press the
SLEEP button to initiate the SLEEP
mode. In this mode, the selected temperature will
increase by 2°F (1°C) 30 minutes after the mode is
selected. The temperature will then increase (cooling)
or decrease (units with heating only) by another
2°F (1°C) after an additional 30 minutes. This new
temperature will be maintained for 6 hours before it
returns to the originally selected temperature. This
ends the SLEEP mode and the unit will continue
to operate as originally programmed. The SLEEP
mode program can be canceled at any time during
operation by pressing the SLEEP button again.
CHECK FILTER FEATURE:
Press the
CHECK FILTER button to initiate this
feature. This feature is a reminder to clean the Air
Filter for more efficient operation. The LED (light) will
illuminate after 250 hours of operation. To reset after
cleaning the filter, press the CHECK FILTER button
and the light will go off.
ENERGY SAVER FEATURE:
Press the
ENERGY SAVER button to initiate this
function. This function is available on COOL, DRY
and AUTO (only AUTO-COOLING and AUTO-FAN)
modes. In this mode, the fan will continue to run for 3
minutes after the compressor shuts off. The fan then
cycles on for 2 minutes, at 10 minute intervals, until
the room temperature is above the set temperature,
at which time the compressor turns back on and
cooling starts.
FOLLOW ME FEATURE:
This feature can ONLY be activated
Light
from the remote control. The
Flashing
Follow
remote control serves as a remote
Me
thermostat allowing for precise
temperature control at its location.
To activate the Follow Me feature, point the remote
control toward the unit and press the FOLLOW ME
button. The remote displays the actual temperature
at its location. The remote control will send this
signal to the air conditioner every 3 minutes until the
FOLLOW ME button is pressed again. If the unit does
not receive the Follow Me signal during any 7 minute
interval, the unit will beep to indicate use of the
Follow Me feature has ended. The actual temperature
can be displayed at the unit by pressing the FAN only
mode. When in the COOL mode, the unit display
indicates the set temperature.
11
TO SELECT THE OPERATING MODE:
To choose operating mode, press the
button. Each time you press the button, a mode is
selected in a sequence that goes from AUTO, COOL,
DRY, HEAT (for units with heating function) and FAN.
The indicator light will be illuminated and remain on
once the mode is selected. The unit will automatically
initiate the Energy Saver function under COOL, DRY, and
AUTO (only AUTO-COOLING and AUTO-FAN) modes.
TO OPERATE AUTO FEATURE:
When you set the air conditioner in AUTO mode, it
will automatically select cooling, heating (on models
with heating capabilities) or fan only operation
depending on what temperature you have selected
and the room temperature. The air conditioner will
automatically control room temperature around the
temperature you set. In this mode, the fan speed
cannot be adjusted. It starts automatically at a speed
according to the room temperature.
TO OPERATE FAN ONLY:
Use this function (
) only when cooling is not
desired, such as for room air circulation or to exhaust
stale air. (Remember to open the vent during this
function, but keep it closed during cooling for
maximum cooling efficiency.) You can choose any
fan speed you prefer. During this function, the display
will show the actual room temperature, not the set
temperature as in the cooling mode.
TO OPERATE DRY MODE:
In this mode, the air conditioner will reduce air
humidity. If the space is a closed or sealed area,
some degree of cooling will continue.
TIMER: AUTO START/STOP FEATURE:
● When the unit is on or off, press the
button. The TIMER ON indicator light illuminates
and indicates the Auto Start program is initiated.
● When TIMER ON is displayed, pressing the TIMER
button again illuminates the TIMER OFF indicator
and indicates the Auto Stop program is initiated.
● Press or hold the UP or DOWN button to change
the Auto time by 0.5 hour increments, up to 10
hours, then by 1 hour increments, up to 24 hours.
The control will count down the time remaining
until start.
● The selected time will register in 5 seconds and
the system will automatically revert back to
displaying the previous temperature setting or the
room temperature (depending on whether the unit
is powered on or off and the mode it is in).
● Turning the unit ON or OFF at any time or
adjusting the timer setting to 0.0 will cancel the
Auto Start/Stop program.
A NOTE ABOUT THE TIMER: When you set the timer, the
unit will only go on once and off once. If you want the
air conditioner to cycle on and off based on desired
room temperature, you do not need to set the timer.
Instead, set your desired temperature and the unit will
cycle on and off based on that temperature setting.