Download Print this page

Vision ZM 1601 EU Installation & Operation Manual page 2

Wireless siren & strobe alarm battery power

Advertisement

Introduction
Thanks for choosing the Vision's wireless siren & strobe alarm of the home security device.
This siren is a Z-Wave™ enabled device (interoperable, two-way RF mesh networking
technology) and is fully compatible with any Z-Wave™ enabled network. Every main
powered Z-Wave™ enabled device acts as a signal repeater and multiple devices result in
more possible transmission routes which helps eliminate "RF dead-sports".
Z-Wave™ enabled devices displaying the Z-Wave™ logo can also be used with it
regardless of the manufacturer, and ours can also be used in other manufacturer's
Z-Wave™ enabled networks. This product will sound a loud siren and flash a strobe light
when an alarm message or alert is received on any Z-Wave™ enabled network.
Product Description and Specification
*** For indoor use only ***
LED setting light
Specification:
Protocol: Z-Wave™ (ZM3102N)
Frequency Range:
868.42MHz (ZM1602EU)
908.42MHz (ZM1602US)
921.42MHz (ZM1602BR)
Operating Range: Up to 100 feet line of sight
Loud Audible Alarm: > 105Db@1meter
LED Strobe Lighting
Operating Temp.: -15°C~ 60°C (5°F~140°F)
Battery: 4pcs x AA Energizer Batteries
Z-Wave™ Command Classes:
COMMAND_CLASS_BASIC
COMMAND_CLASS_BATTERY
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_MANUFACTURER_SPECIFIC
COMMAND_CLASS_SWITCH_BINARY
COMMAND_CLASS_VERSION
Note: COMMAND_CLASS_BASIC Mapping
Package Content:
1pc
ZM 1601 Siren
1pc
Adhesive tape
2pcs
Screw
4pcs
AAEnergizer Batteries
1pc
Installation & Operation
Manual
COMMAND_CLASS_SWITCH_BINARY
-1-
Installation
Note: If you are installing the entire Z-Wave™ system for the first time, please refer to the
installation guide of Z-Wave™ Interface Controller before installing ZM 1601.
1.
Remove the bracket from the siren by press the locking tab, and then gently slide
up the siren. Observe the correct polarity before insert the batteries.
2.
Using the screws or adhesive tape to affix the bracket on the chosen location.
Slide back the cover and screw fastening with the front cover, the LED should go off.
3.
4.
For "Inclusion" in (adding to) a network: Put the Z-Wave™ Interface Controller
into "inclusion" mode, and following its instruction to add the ZM 1601 to your
controller. To get in the "inclusion" mode, the distance between siren and controller
is suggested to be in one meter. Open the bracket and press the program switch of
ZM 1601 for 1 second at least & release to be included. After setting, the LED
Setting Lighting should go off, if not, please try again.
For "Exclusion" from (removing from) a network: Set up the Z-Wave™ Interface
Controller into "exclusion" mode, and following its instruction to delete the ZM 1601
from your controller. Press the program switch of ZM 1601 for 1 second at least &
release to be excluded.
Note: LED setting light will flash (orange color) continuously in Exclusion condition.
5.
Configuration command class:
Parameter 0: Siren/ Strobe Mode, 1 Byte Value: 0=siren and Strobe enable
(default), 1=siren only, 2= Strobe only.
Parameter 1: Alarm auto stop time command, 0=30 seconds (default), 1= 60 secs,
2= 120 secs, 3= siren will not automatically stop.
Operation
1.
Normal operation, the LED light will not on.
2.
Self-Protection Mode: After put back the bracket over 5 seconds, ZM 1601 will enter
Self-Protection Mode. If the back cover is opened will trigger the Self-Protection
Mode. The alarm time is default 30 seconds.
3.
User's controller should support Z-wave FLiRS technology.
4.
Alarm Mode (It's the status of alarm triggered): It's based on the user's
configuration setting of LED flash ON/OFF and Siren ON/OFF.
Note: for Default setting-Siren/Strobe Mode-Parameter will be All enable; Alarm
Auto Stop Time-Parameter will be 30 sec.
5.
For safety reason, replace new battery whenever ZM 1601 is triggered.
-2-

Advertisement

loading

This manual is also suitable for:

Zm 1601 usZm 1601 br