Maintenance And Care; Maintenance Intervals; Cleaning The Machine - Pfaff 3538-30/02 Instruction Manual

Hide thumbs Also See for 3538-30/02:
Table of Contents

Advertisement

Maintenance and Care

11
Maintenance and Care
11

Maintenance intervals

.01
11

Cleaning the machine

.02
The required cleaning cycle for the machine depends on the following factors:
 Single or multi-shift operation
 Dust formation caused by the workpieces
Optimal cleaning instructions can therefore only be determined on a case-by-case basis.
The following tasks are recommended during a single shift operation to avoid operational er-
rors:
 Open the hook area cover.
 Clean the hook area daily, more frequently during continuous operation.
 Close the gripper area cover!
38
Cleaning the hook area .............................daily, several times during continuous operation
Cleaning the complete machine ............................................................................... weekly
Machine oil level .................................................................................. daily, before start-up
Checking / setting the air pressure ...................................................................... as needed
Cleaning the maintenance unit air fi lter ............................................................... as needed
These maintenance intervals are based on an average running time of a single
shift production shop. Shorter maintenance intervals are recommended for in-
creased running times.
Disconnect the machine from the electricity mains for all cleaning work by shut-
ting off the main switch or removing the mains plug! Risk of injury due to acci-
dental machine start-up!
Only operate the machine when the hook room cover is closed!
Risk of injury due to moving parts!

Advertisement