Computer-controlled leveling system spacemaker room extension system
Table of Contents

Advertisement

BREATHER CAP - DIPSTICK - 1/4" NUT DRIVER
VALVE RELEASE
NUT
NOTE: THE BREATHER CAP IS LOCATED
ON THE TOP SIDE OF THE POWER UNIT RESERVOIR.
OIL LEVEL
IMPORTANT: PRIOR TO REMOVING THE BREATHER CAP,
EITHER TO CHECK THE OIL LEVEL OR TO USE THE 1/4" NUT DRIVER,
CLEAN ANY DEBRIS FROM THE TOP OF THE RESERVOIR.
BEFORE RETURNING THE BREATHER CAP TO THE RESERVOIR,
REMOVE ANY PAINT CHIPS OR OTHER DEBRIS FROM THE DIPSTICK
INCLUDING DEBRIS INSIDE THE 1/4" NUT DRIVER.
THE 1/4" NUT DRIVER IS USED TO OPEN
THE VALVE RELEASE NUT ON THE 1 1/2"
DIAMETER SOLENOID VALVES.
NOTE: DO NOT turn the valve
release nut more than 4 and 1/2
(four and one half) turns counter
clockwise. Damage to the valve
may result.
1/4" NUT DRIVER
OIL LEVEL GROOVES
BREATHER CAP
1 1/2" DIAMETER
SOLENOID VALVE
MP85.999X
27MAR02