HWH 680 Series Operator's Manual page 37

Computer-controlled leveling system spacemaker room extension system
Table of Contents

Advertisement

ELECTRICAL CONNECTION DIAGRAM
UPPER FRONT LOCK
B A
B A
6120
5708
LOWER FRONT LOCK
B
A
B
A
6120
5706
(1) UPPER FRONT UNLOCK - 5704
(2) UPPER REAR UNLOCK - 5705
(3) LOWER FRONT UNLOCK - 5706
(4) LOWER REAR UNLOCK - 5707
(5) UPPER FRONT LOCK - 5708
(6) UPPER REAR LOCK - 5709
(7) LOWER FRONT LOCK - 5710
(8) LOWER REAR LOCK - 5711
LEVEL FLOOR ROOM EXTENSION
LIMIT SWITCHES
FLOOR
DOWN
LIMIT
SWITCH
FLOOR
DOWN
C B
A
FLOOR
UP
LIMIT
SWITCH
5714
6120
C B A
5701
5710
6120
UPPER REAR LOCK
ROOM
IN
LIMIT
SWITCH
ROOM IN
P.E.D
ROOM
OUT
LIMIT
SWITCH
5703
6120
LOWER REAR LOCK
P.E.D
5713
6120
5711
SEE ELECTRICAL CONNECTION DIAGRAM
LIMIT SWITCH INDICATOR BOX - LEVEL FLOOR
ROOM EXTENSION
B A
B A
5709
6120
B A
B
A
5707
6120
(15) +12 VOLTS - 6120
(14) FLOOR UP - 5713
(13) ROOM IN - 5703
(8) FLOOR DOWN - 5714
(7) ROOM OUT - 5701
MP85.486F
01FEB00

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents