Appendix 2

TOUCH-UP ON TIMER

This option allows the static convergence to be carried out auto-
matically after a user-defined time, which can be programmed in
hours and/or minutes.
To program the touch-up on Timer:
Push up or down keys of the control disc to highlight ON
TIMER: off;
Press the <ENTER> button to switch it to ON and the pre-
set time will be displayed;
Press the <TEXT> button to enter the TOUCH-UP TIMER
menu;
Push left or right keys of the control disc to highlight the
digit to be changed;
Use the numeric keys to enter a desire value;
Press the <ENTER> button to confirm and the EYE-Q
SETUP menu will return on the screen; or press the <EXIT>
button to leave the preset value untouched and return to the
EYE-Q
SETUP menu.
TM
Press the <EXIT> button to return to the EYE-Q
When one adjust geometry by hand, a reference screen and a
reference pattern are required. There are a lot of possibilities for
a reference screen. A test pattern for a video test disc is nor-
mally used. See geometry section of manual for more informa-
tion. Once a selection of a reference screen and a reference pat-
tern is made, adjusting geometry is only a matter of converging
these two elements.
EYE-Q
requires a reference for adjusting geometry. The sim-
TM
plest way to have a reference screen is to adjust one source by
hand, which then serves as a reference for all other sources.
After adjusting a source, the reference is learned by EYE-Q
and stored in non-volatile memory. Having this Reference
Source in memory EYE-Q
the same geometry as the Reference Source.

REFERENCE SOURCE

Before any geometric adjustment can be done, the user Must
learn a Reference Source. This process is ONLY DONE ONCE
since the Reference will be stored in non-volatile memory. If
however, the projector is moved from its position, then the Learn
Reference procedure must be repeated. After learning a Refer-
ence do not touch the camera (for focusing and centering).
If using multi-aspect ratios, a Reference Geometry must be done
for each aspect ratio.

ADJUSTING OTHER SOURCES

Once a Reference Source is in memory, other sources are
aligned with the same geometry as the Reference Source. If no
Reference Source is learned, the resulting geometry will be
unpredictable.
can adjust all other sources to have
TM
TOUCH UP
AUTOCONVERGENCE
QUICK AUTOPICTURE
FULL AUTOPICTURE
EYE-Q SETUP
EYE-Q DIAGNOSTICS
Select with
then <ENTER>.
<EXIT> to return
TM
CENTER THE CAMERA
CONFIGURATION: rear/front
TOUCH-UP OPTIONS:
menu.
TM
TM
APX-8
EYE-Q
or
EYE-Q SETUP
FOCUS THE LENS
CENTER THE CAMERA
CONFIGURATION: rear/front
LEARN REFERENCE
TOUCH-UP OPTIONS:
Select with
or
then <ENTER>.
<EXIT> to return
TOUCH-UP OPTIONS
ON SOURCE SWITCH : on/off
ON TIMER : on/off
-h.- min.
Select with
or
then <ENTER>.
<EXIT> to return
EYE-Q SETUP
FOCUS THE LENS
LEARN REFERENCE
Select with
or
then <ENTER>.
<EXIT> to return