Indoor Wiring Diagram :
Model : JB-B2258QC (R410 Gas Charge Model)
NOTE : Connect IR PCB Assy. at CN-DISP of PCB Assy.
Outdoor Wiring Diagram :
Model : JB-B2258QC (R410 Gas Charge Model)
RD
RD
18
15
3
ø
MONITORING
RELAY
L3
L2
L1
RD
34
34
RD
35
RD
1
2
L
N
HP
LP
To Indoor
SWITCH
SWITCH
(1Ø,230V)
SENSOR
SENSOR
JUMPER
ASSY.
CN-PIPE/IN
CN-VM
CN-FLOAT
CONTROLLER
COMP
T 3
T1
T2
BL
RD
WH
BK
L1
L2
L3
A1
Magnetic
Contactor
A2
T1
T2
T3
BK
RD YL
BL
RD
YL
BL
RD
RD
BK
3
4
5
6
1 2 3
G
R S
T
S
N
From Indoor
3Ø 415V
Power Supply
NOTE: 1) For ANONE1 Model Suffix, CN-DISP is Optional.
2) For ANONE2 Model Suffix, WIRED REMOTE CONTROLLER
& DRAIN PUMP is Optional.
CN-POWER
RY-D/PUMP
FUSE 250V
3.15A
MOTOR
1
ORANGE
BK
YELLOW
CAPACITOR
TERMINAL C
BK
TERMINAL A
3854A20396B
20
RD
BL
BR
BK
FROM OUTDOOR
3854A20298K