Indoor Wiring Diagram :
Model : JB-B2156QC (R410 Gas Charge Model)
NOTE : Connect IR PCB Assy. at CN-DISP of PCB Assy.
Outdoor Wiring Diagram :
Model : JB-B2156QC (R410 Gas Charge Model)
1ph 230V
3 2 1
4 5 6 78 9
HP
SWITCH
BR
GR
FUSE
BL
BR
GR
GR
BL
BL
A1
A2
L1
T1
Magnetic
Contactor
L2
T2
OUTDOOR WIRING DIAGRAM
SENSOR
SENSOR
JUMPER
ASSY.
CN-PIPE/IN
CN-VM
CN-FLOAT
CONTROLLER
To
Indoor
OUT
MOTOR
GR
BK
WH
BK
T/B1
T/B2
BR
BL
NOTE: 1) For ANONE1 Model Suffix, CN-DISP is Optional.
2) For ANONE2 Model Suffix, WIRED REMOTE CONTROLLER
& DRAIN PUMP is Optional.
CN-POWER
RY-D/PUMP
FUSE 250V
3.15A
OR(GR)
RD
S
C
COMP
R
H
C
YL
BK
F
3854A20372B