Sub Volume (Installer Adjust mode): Select Sub Volume from the Set-Up menu to
adjust the audio input level for the current source. Do this for all sources, as needed to
prevent sudden, drastic changes in sound volume when switching inputs.
For example, if a DVD player is connected to Input 4, a computer is connected to Input 1
and the audio output of the DVD player is fixed at a much higher level than that of the
computer, reduce the Sub Volume for Input 4.
The Sub Volume control affects the current input only; the front-panel and remote volume
controls are "master" controls; see Figure 4-7.
1 AUDIO INPUT
INPUT1
(INPUT1)
SUB VOLUME
INPUT2
2 AUDIO INPUT
SUB VOLUME
(INPUT2)
INPUT3
3 AUDIO INPUT
SUB VOLUME
(INPUT3)
INPUT4
4 AUDIO INPUT
SUB VOLUME
(INPUT4)
INPUT5
5 AUDIO INPUT
SUB VOLUME
(INPUT5)
Figure 4-7. Audio System Functional Block Diagram
Language: Refer to Changing the OSD Language on page 27.
Energy Mode: Select Energy Mode from the Option menu to reduce power
consumption and panel deterioration by limiting brightness of the screen. You can choose
to limit brightness according to the input signal or in response to the ambient light level.
• Select AVERAGE to limit brightness in accordance with the input signal to produce a
bright, easily viewed image.
• Select LEVEL 1 to limit brightness in accordance with the input signal. Power
consumption is less than that used in AVERAGE mode.
• Select LEVEL 2 to limit brightness in accordance with the input signal. Power
consumption is less than that used in LEVEL1 mode.
• Select LEVEL 3 to set the brightness at fixed level, regardless of input signal level
(useful for preventing screen aging due to image burn).
• Select AUTO (Model SP-42), AUTO1 or AUTO2 (Model SP-50/SP-60) to have the
CinemaWall adjust the brightness automatically in response to ambient lighting
conditions, to optimize picture quality.
• To disable the Energy Mode feature, select MUTE.
Runco CinemaWall SP Series Owner's Operating Manual
INPUT
POWER
SELECTOR
AMPLIFIER
VOLUME
41
Operation

Option

CINEMAWALL
PICTURE
SCREEN
SET-UP
OPTION
LANGUAGE
: ENGLISH
ENERGY MODE
: AUTO
TIME / DATE
PDP MGMT.
AUTO SETUP MODE
: OFF
AUTO FUNCTION
: OFF
SET
ENTER
MENU
EXIT
INPUT 3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents