The time on the programmer must be correct. Some types have to be
adjusted in spring and autumn at the changes between Greenwich
Mean Time and British Summer Time.
You may be able to temporarily adjust the heating programme, for
QEG-2
example, 'Override', 'Advance', or 'Boost'. These are explained in the
QEG-2S
manufacturer's instructions.
The heating will not work if the room thermostat has switched the
EN
Operating Manual
heating off. And, if you have a hot-water cylinder, the water heating
will not work if the cylinder thermostat detects that the hot water has
reached the correct temperature.
HOT WATER
HEATING
Override
Override
Thu
07 / 02 / 2013
Extra Hour
Extra Hour
am
Description of the device
OFF
OFF
Your two channel programmer provides timing control for your central
Mode
AUTO
AUTO
Mode
ONCE
ONCE
heating and domestic hot water, letting you set ON and OFF periods to
CONT
CONT
EXT HOUR
EXT HOUR
ON1
+1
ON1
+1
suit your own lifestyle.
+2
+2
+3
+3
• Backlit lCD Display
• Real Time Clock
Holidays
• Up to 3 ON/OFF per day
DAY/
DHW
CH
RUN
TIME
OK
• Automatic summertime / wintertime changeover
• Daily, weekly
Select
• Different running modes: OFF, AUTO, ONCE, CONTINUOUS and
HOlIDAYS
1)
• Manual override function
• Manual extra hour function
• 3 different pre-programmed profi les, customizable by user
• Boiler service interval indication & actions
Grässlin GmbH
Designated use
Bundesstraße 36
• The programmer is used to control central heating zone systems or
D-78112 St. Georgen
combi boilers and domestic hot water systems ("fully pumped" or
Germany
"gravity-fed").
Phone: +49 7724 933-0
• Suitable for use in dry rooms only!
Fax: +49 7724 933-240
• Do not install in the vicinity of devices which generate inductive
www.graesslin.de
discharges (motors, transformers, etc.)
info@graesslin.de
Technical data
Dimensions H x W x D (mm)
Weight g (approx.)
Power supply
More information on our web page:
Power consumption
http://qeg.graesslin.de/qrcode/im/qeg2/
Power reserve
Switching capacity
Time display
Time setting resolution
– Time of day
– Programmes / min. switching
Programmes
Number of switchings per day
Safety Instructions
Operating temperature range
Danger! Risk of electric shock!
Ambient temperature
Humidity range
Installation must be carried out by a
Z
Z
Accuracy
WARNING
professional electrician!
Terminal capacity
Protection type
• To avoid injuries, the device must be installed by a skilled
European standards
electrician only!
• Before changing the battery, the device must be disconnected
from the power supply!
• Please observe the national regulations and safety instructions.
• Interferences and changes to the device will invalidate the
warranty and guarantee rights.
• Maximum diameter of the conductors lines for the
2
terminals: 2 x 2,5 mm
Installation und Montage
Installation and mounting
Read and observe these instructions to guarantee a perfect function
of the device and a safe operation.
WARNING
General information
Information about the device
What is a programmer?
...an Explanation for Householders (as recommended by the Energy
Savings Trust)
Programmers allow you to set 'ON' and 'OFF' time periods. Some
models switch the central heating and domestic hot water on and
off at the same time, while others allow the domestic hot water and
heating to come on and go off at different times.
Set the 'ON' and 'OFF' time periods to suit your own lifestyle. On
some programmers you must also set whether you want the heating
and hot water to run continuously, run under the chosen 'ON' and
'OFF' heating periods, or be permanently off.
1)
Function not available for all products.
80.10.1352.7_manual_QEG2_QEG2S_FERTIG_V02.indd 1
Open/Close housing, Wall mounting
Wiring diagram
1)
and week-weekend
1)
programming possibility
1)
230 V / 50-60 Hz
N
L
95 x 148 x 36
Quick-start guide – 3 clicks to total control
285
230 V AC / 50-60 Hz
< 3 W
1.
Connect mains power.
> 2h
2.
Press OK three times.
3 A 250 V ~ resistive, cos φ = 1
Z
Z
The default Standard in-built programme runs.
3 A 250 V ~ inductive, cos φ = 0.6
You can control the QEG with the Override, Extra Hour or Mode
Z
Z
buttons.
24 h or 12 h AM/PM format
1 min.
Please read the full instructions if you want to know more.
1 min.
Selectable (daily , weekly, or
week-weekend)
Operation and confi guration
3 ON/OFF pairs
(2 ON/OFF pairs selectable)
0°C ... + 45°C
Display / Function keys
-20°C ... + 55°C
10 to 90% RH, non condensing
HOT WATER
Type ± 1 sec./day at +20°C
Override
2 x 2,5 mm
2
07 / 02 / 2013
IP 30
Extra Hour
EN60730-2-7
OFF
Mode
AUTO
Compliant with building regulations
ONCE
CONT
(Part l Uk) (Part J Scotland)
EXT HOUR
ON1
+1
+2
+3
1)
1)
Holidays
OK
Danger! Risk of electric shock!
Day of the week indicator
A
Current day, month, year
b
Z
Z
Installation must be carried out by a
C
Central heating operating
professional electrician!
mode indicator
D
Central heating override
button
Central heating extra hour
E
button
F
Central heating operating
mode button
G
Central heating indicator lamp
H
Central heating extra hour
indication
1.5 m
Central heating programming
I
period indication
J
Select indicator lamps
K
Select
L
Ok button
"-" and "+" button
M
Holiday button
N
1)
O
1)
Holiday icon
Commissioning
When fi rst using the timer, you have to set programming type,
date and time.
PROG TYPE
DAY
MONTH
YEAR
HOUR
MINUTE
DONE
1.
Connect the programmer to power.
Z
Z
Product name and version number are displayed briefl y.
Z
Z
The preset PROGRAMMING TYPE and OK are fl ashing.
Depending on the product you can choose between three different
settings: Daily, Weekly
or Week-Weekend
1)
Daily
All days (Monday - Sunday) are programmed
with the same ON/OFF time schedule
N L 1 2 3 4
Weekly
You can program each day (Monday, Tuesday,
1)
...) with a different ON/OFF time schedule
Week-Weekend
1)
You can program Monday - Friday with a ON/
CH
CH
OFF
ON
OFF time schedule and Saturday - Sunday with
HW
HW
a different one.
OFF
ON
2.
Choose your desired programming type (DAIlY, WEEklY
WEEk-WEEkEND
),
or
, and confi rm with
1)
Z
Z
Preset value DATE is fl ashing.
3.
Enter day,
or
, and confi rm with
.
Z
Z
Preset value MONTH is fl ashing.
4.
Enter month,
or
, and confi rm with
Preset value YEAR is fl ashing.
Z
Z
5.
Enter year,
or
, and confi rm with
.
Z
Z
Preset TIME is fl ashing.
6.
Enter hour,
or
, and confi rm with
.
Z
Z
Preset value MINUTE is fl ashing.
7.
Enter minute,
or
, and confi rm with
The date and time are saved.
Z
Z
The programmer goes to RUN mode.
Z
Z
Set date and time
If you wish to change the date or time, follow the instructions below:
DAY/
DHW
CH
RUN
TIME
DAY
HEATING
MONTH
Override
Thu
YEAR
am
Extra Hour
HOUR
OFF
AUTO
Mode
ONCE
MINUTE
CONT
HOT WATER
HEATING
EXT HOUR
ON1
+1
+2
Override
DONE
Override
Thu
+3
07 / 02 / 2013
Extra Hour
am
Extra Hour
OFF
OFF
Mode
AUTO
AUTO
Mode
ONCE
ONCE
CONT
CONT
DAY/
DHW
CH
RUN
EXT HOUR
EXT HOUR
TIME
ON1
+1
ON1
+1
+2
+2
+3
+3
Holidays
DAY/
DHW
CH
RUN
Select
TIME
OK
1.
Press the SELECT
until menu DAY/TIME is selected.
Select
Z
Z
Select indicator lamp DAY/TIME is ON.
Information text line
2.
Enter day,
or
, and confi rm with
.
P
Domestic hot water
Preset value MONTH is fl ashing.
Q
Z
Z
programming period
3.
Enter month,
or
, and confi rm with
indication
Z
Z
Preset value YEAR is fl ashing.
R
Domestic hot water extra
4.
Enter year,
or
, and confi rm with
.
HOT WATER
HEATING
Override
Override
hour indication
Z
Z
Preset TIME is displayed.
Thu
07 / 02 / 2013
Extra Hour
am
Extra Hour
Domestic hot water indicator
5.
Enter hour,
or
, and confi rm with
.
S
OFF
OFF
Mode
AUTO
AUTO
Mode
lamp
Preset value MINUTE is fl ashing.
ONCE
ONCE
Z
Z
CONT
CONT
EXT HOUR
EXT HOUR
ON1
+1
ON1
+1
+2
+2
+3
+3
T
Domestic hot water operating
6.
Enter minute,
or
, and confi rm with
mode button
Z
Z
The date and time are saved.
Holidays
DAY/
DHW
CH
RUN
TIME
OK
U
Analog clock / current time
7.
Press the SELECT
until indicator lamp RUN is ON.
Select
V
Domestic hot water extra
hour button
Domestic hot water override
Change AM/PM time display to 24 hour clock
W
button
Your programmer can operate on the 12 hour AM/PM or 24 hour clock
X
Domestic hot water icon
formats.
Y
Warning icon
If you wish to change the clock format, follow the instructions below:
Z
Domestic hot water operating
10 sec.
mode indicatior
INST MENU
DIGI CLOCK
12 24 HRS
1.
Make sure the device is working in RUN mode.
2.
Press and hold
buttons at the same time for 10 seconds.
INST MENU opens and OK is fl ashing.
Z
Z
3.
Confi rm with
.
Z
Z
The menu item DIGI CLOCK is displayed.
4.
Press
to edit settings.
Setting NO is fl ashing.
Z
Z
5.
Press
or
to scroll through the menu. Choose YES and
confi rm with
.
Z
Z
Setting AM PM is fl ashing.
6.
Press
or
to scroll through the menu. Choose AM PM or 24
HRS and confi rm with
.
The chosen setting is saved.
Z
Z
The next menu item bACKLIGHT is displayed.
Z
Z
7.
To save your settings, continue scrolling through the menu options
with
key, until you once again see INST MENU / – OK +, and
fi nally leave the installers menu with
key.
With QEG-2S, continue scrolling through the menu options with
key, until you see CHANGE PIN / – OK +, and fi nally leave the
installers menu with
key.
Running a built-in programme (default programmes)
With the date and time correct, your timer will now be operating to the
built-in programmes. These have been designed to provide heating at
.
typical times throughout the day.
1)
The built-in programmes give you a starting point that you can
personalise to your own requirements, please see the section "Review/
Edit central heating program" or "Review/Edit domestic hot water
program".
Built-in programme STD (DEFAUlT)
Daily
ON1: 06:30 am
ON2: 12:00 pm*
ON3: 04:30 pm
OFF1: 08:30 am
OFF2: 12:00 pm*
OFF3: 10:30 pm
Weekly
1)
ON1: 06:30 am
ON2: 12:00 pm
ON3: 04:30 pm
OFF1: 08:30 am
OFF2: 01:00 pm
OFF3: 10:30 pm
,
1)
.
Week-
ON1: 06:30 am
ON2: 12:00 pm
ON3: 04:30 pm
Weekend
1)
OFF1: 08:30 am
OFF2: 01:00 pm
OFF3: 10:30 pm
ON1: 06:30 am
ON2: 12:00 pm
ON3: 04:00 pm
OFF1: 09:30 am
OFF2: 01:00 pm
OFF3: 10:30 pm
.
Built-in programme HOME
Daily
ON1: 06:30 am
ON2: 12:00 pm*
ON3: 04:00 pm
OFF1: 09:30 am
OFF2: 12:00 pm*
OFF3: 11:00 pm
Weekly
1)
ON1: 06:30 am
ON2: 12:00 pm
ON3: 04:00 pm
.
OFF1: 09:30 am
OFF2: 01:00 pm
OFF3: 11:00 pm
Week-
ON1: 06:30 am
ON2: 12:00 pm
ON3: 04:30 pm
Weekend
1)
OFF1: 09:30 am
OFF2: 01:00 pm
OFF3: 11:00 pm
ON1: 06:30 am
ON2: 12:00 pm
ON3: 04:00 pm
OFF1: 09:30 am
OFF2: 01:00 pm
OFF3: 11:00 pm
Built-in programme ECO
Daily
ON1: 06:30 am
ON2: 12:00 pm*
ON3: 05:30 pm
OFF1: 07:30 am
OFF2: 12:00 pm*
OFF3: 10:00 pm
Weekly
1)
ON1: 08:30 am
ON2: 12:00 pm
ON3: 05:30 pm
OFF1: 09:30 am
OFF2: 01:00 pm
OFF3: 10:00 pm
Week-
ON1: 06:30 am
ON2: 12:00 pm
ON3: 05:30 pm
Weekend
1)
OFF1: 07:30 am
OFF2: 12:00 pm
OFF3: 10:00 pm
ON1: 08:30 am
ON2: 12:00 pm
ON3: 05:30 pm
OFF1: 09:30 am
OFF2: 01:00 pm
OFF3: 10:30 pm
* On/off prgrammes with the same time cancel out - no switching will occur.
The built-in programmes can be selected in the INSTALLERS MENU.
To access to installers menu, the device must be working in RUN mode.
10 sec.
INST MENU
.
DIGI CLOCK
BACKLIGHT
S W CHANGE
PROG TYPE
.
1.
Make sure the device is working in RUN mode.
2.
Press and hold
buttons at the same time for 10 seconds.
Z
Z
INST MENU opens and OK is fl ashing.
3.
Confi rm with
.
Installers menu is activated.
Z
Z
4.
Press 3 x
until PROG TYPE is displayed.
5.
Press
to edit settings.
Z
Z
Preset value is fl ashing.
6.
Press
or
to scroll through the menu. Choose your desired
setting (DAIlY, WEEklY
, 5-2 DAYS
) and confi rm with
1)
1)
Z
Z
The chosen setting is saved.
The next menu item NR PERIODS is displayed.
Z
Z
NR PERIODS
DEFAULT PROG
PUMP GRAVITY
7.
Press
to go to DEFAULT PROG.
8.
Press
to edit settings.
Preset value is fl ashing.
Z
Z
9.
Press
or
to scroll through the menu. Choose your desired
setting (STD, HOME or ECO) and confi rm with
.
Z
Z
The chosen setting is saved
Z
Z
The next menu item PUMP GRAVITY is displayed.
10. To save your settings, continue scrolling through the menu options
with
key, until you once again see INST MENU / – OK +, and
fi nally leave the installers menu with
key.
With QEG-2S, continue scrolling through the menu options with
key, until you see CHANGE PIN / – OK +, and fi nally leave the
installers menu with
key.
Domestic hot water systems
1)
– "fully pumped system" or "gravity-fed system
Fully pumped
The term for any boiler that uses a pump to
Domestic Hot Water
move all the heat from the boiler to every
system
part of the system is "fully pumped". As a
(PUMPED)
rule one pump is used to circulate the water
through valves which divert the fl ow to the
relevant part of the system (Central heating or
Domestic Hot water). In this type of systems,
both channels of the programmer can work
independently.
Mo - Fr
Gravity-fed
In gravity fed hot water systems, whenever
Sa - Su
Domestic Hot Water
the boiler comes on to service heating, there
system
will inevitably be some circulation through
(GRAVITY)
the hot water storage tank, which will then
heat up. Then there is no possibility to have
independent programs for heating and hot
water.
You can choose the desired system in the INSTALLERS MENU.
To access to installers menu, the device must be working in RUN
mode.
Mo - Fr
10 sec.
Sa - Su
INST MENU
DIGI CLOCK
BACKLIGHT
S W CHANGE
PROG TYPE
NR PERIODS
DEFAULT PROG
Mo - Fr
PUMP GRAVITY
Sa - Su
RESET
1.
Make sure the device is working in RUN mode.
2.
Press and hold
buttons at the same time for 10 seconds.
INST MENU opens and OK is fl ashing.
Z
Z
3.
Confi rm with
.
Z
Z
Installers menu is activated.
4.
Press 6 x
until PUMP GRAVITY is displayed.
5.
Press
to edit settings.
Preset value is fl ashing.
Z
Z
6.
Press
or
to scroll through the menu. Choose your desired
setting (PUMPED OR GRAVITY) and confi rm with
.
Z
Z
The chosen setting is saved.
Z
Z
The next menu item RESET is displayed.
7.
To save your settings, continue scrolling through the menu
options with
key, until you once again see INST MENU / –
OK +, and fi nally leave the installers menu with
key.
With QEG-2S, continue scrolling through the menu options with
key, until you see CHANGE PIN / – OK +, and fi nally leave
the installers menu with
key.
.
24.04.2013 11:36:47
Need help?
Do you have a question about the QEG-2 and is the answer not in the manual?
Questions and answers