This Appliance Must Be Earthed - Baxi Maxflow Combi WM User Operating Instructions Manual

Gas fired wall mounted combination boiler with unvented hot water storage

Advertisement

STANDARD
B.S. 6891
B.S. 5440: Pt 1
B.S. 5440: Pt 2
B.S. 5546
B.S. 7074
B.S. 5449: Pt 1
B.S. 6798
"Benchmark" Installation, Commissioning and Service Record
Log Book
Please ensure that your installer has completed the Installation and
Commissioning sections of the Log Book and hands the Log Book over.
The details of the Log Book will be required in the event of any warranty
work. Keep the Log Book in a safe place and ensure that the relevant
sections are completed at each subsequent regular service visit.
All CORGI registered installers carry a CORGI identification card and have
a registration number. Both should be recorded in your boiler Log Book.
You can check your installer is registered by telephoning 01256 372300 or
writing to:-
1 Elmwood,
Chineham Business Park,
Crockford Lane,
Basingstoke
RG24 8WG
NOTE: Adjacent to the boiler at either the left
or right hand side there will be fitted an
expansion vessel, relief valve. tundish etc.
These components must not be adjusted or
interfered with in any way. They are part of the
Unvented Hot Water Kit and are important
safety items.
IN AN EMERGENCY
If a water or gas leak occurs or is suspected, the boiler can be
isolated at the inlet valves as follows;
1. Turn off the electrical supply and turn the selector switch on
the facia to the OFF position (see 2.2).
2. The isolating valves are positioned under the boiler and can be
closed using either a flat bladed screwdriver or an open ended
spanner across the flats.
3. Turn the gas tap clockwise to the stop position to isolate the
gas supply at the boiler.
4. To isolate the water system, close the three valves fully by
turning clockwise.
5. Call your Service Engineer as soon as possible.
SCOPE
Gas Installation.
Flues.
Air Supply.
Installation of hot water supplies
for domestic purposes.
Expansion vessels and ancillary
equipment for sealed water systems.
Forced circulation hot water systems.
Installation of gas fired hot water
boilers.
1.0 Warnings
1.1
Safe Installation
1. The appliance is suitable for installation only in
G.B. and I.E. and should be installed in
accordance with the rules in force. For Ireland
install in accordance with I.S.813 "I
G
A
". The installation must be
OF
AS
PPLIANCES
carried out by a CORGI Registered Installer or
other registered competent person and be in
accordance with the relevant requirements of
current G
S
(Installation and Use)
AS
AFETY
R
most recent edition, the B
EGULATIONS
R
issued by the Department of the
EGULATIONS
Environment, B
S
UILDING
TANDARDS
(Consolidation) R
EGULATIONS
Scottish Development Department and the L
B
R
. Where no specific
UILDING
EGULATIONS
instructions are given, reference should be made
to the relevant BRITISH STANDARD CODES OF
PRACTICE and INSTALLATION
SPECIFICATIONS.
2. This appliance must be installed in
accordance with the manufacturer's instructions
and the rules in force, and only used in a suitably
ventilated location.
3. Read the instructions before installing or
using this appliance.
4. Any purpose provided ventilation should be
checked periodically to ensure that it is free from
obstruction.
IMPORTANT - The addition of anything that
may interfere with the normal operation of the
appliance without the express written
permission of Baxi UK Limited could invalidate
the appliance warranty and infringe the G
S
(Installation and Use) R
AFETY
1.2
In case of gas leaks
1. If a gas leak is found or suspected, turn off the
gas supply at the meter immediately and at the
isolating valve on the boiler if possible. Contact your
Installer or Transco (under 'Gas' in the 'phone
directory).
1.3
Servicing your Appliance
1. For reasons of safety and economy your
appliance should be serviced annually. Servicing
must be performed by a competent person. Your
Installer or British Gas Service will be able to advise
you.
1.4
Electricity Supply

1. THIS APPLIANCE MUST BE EARTHED.

2. A standard 230V ~ 50H z supply is required. The
appliance must be protected by a 3 amp fuse.
Never Hang Flammable Items Over The
Appliance
NSTALLATION
UILDING
(Scotland)
issued by the
OCAL
AS
.
EGULATIONS
3