ACP OMNISTIM 500 PRO User Manual

ACP OMNISTIM 500 PRO User Manual

Electrotherapy system

Advertisement

OMNISTIM
500 PRO
®
Electrotherapy System

User Manual

Revised 01.22.2018
Part No. 290500C Rev 5
This manual and all content therein is owned exclusively by Accelerated Care Plus ("ACP") and is protected by copyright. This manual or any
portion thereof may not be photocopied, reproduced or translated to another language without the express prior written consent of ACP. This
manual may only be used by entities that have purchased the equipment or have implemented the ACP program and are covered by an executed
lease agreement. This manual may not be used for any other purpose.
Any additional copies of the Manual shall be ordered from ACP. No changes or modifications shall be made to the Manual without prior review
and written authorization from ACP. No authorization is given to market, sell, disclose, or exploit this Manual except as for purposes of using the
Equipment as contemplated by the Lease Agreement.
ACCELERATED CARE PLUS MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS MANUAL, INCLUDING, BUT NOT
LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Accelerated
Care Plus shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance
or use of this Manual.
The information contained in this document is subject to change without notice.
COPYRIGHT © 2004 - 2018, ACCELERATED CARE PLUS CORP., ALL RIGHTS RESERVED

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OMNISTIM 500 PRO and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ACP OMNISTIM 500 PRO

  • Page 1: User Manual

    ACP. This manual may only be used by entities that have purchased the equipment or have implemented the ACP program and are covered by an executed lease agreement.
  • Page 2 ACP is internationally recognized for its contribution to research in the development of medical applications for therapeutic rehabilitation. The Company sponsors and conducts research at leading health care institutions and major universities throughout the world.
  • Page 3: Symbols On The Product

    OMNISTIM ® 500 PRO USER MANUAL SYMBOLS ON THE PRODUCT Symbol Used for Symbol Used for Type BF medical device per: Serial number IEC 60601 Date of manufacture Manufacturer Caution, consult accompanying Caution, electrical precautions documents CE mark of confidence compliant Remote Control connection to MDD (93/42/EEC) Classification against intrusion of...
  • Page 4: Table Of Contents

    OMNISTIM ® 500 PRO USER MANUAL TABLE OF CONTENTS SYMBOLS ON THE PRODUCT ..........................3 ELECTROTHERAPY INDICATIONS & CONTRAINDICATIONS ..............1 Indications ................................1 Contraindications ..............................1 Adverse Reactions .............................. 1 ELECTROTHERAPY WARNINGS & PRECAUTIONS ..................2 Warnings ................................2 Precautions .................................
  • Page 5: Electrotherapy Indications & Contraindications

    OMNISTIM ® 500 PRO USER MANUAL ELECTROTHERAPY INDICATIONS & CONTRAINDICATIONS CAUTION: Federal law restricts this device for sale or use by, or on the order of, a Practitioner licensed by the laws of the state in which he/she practices to use or order the use of the device. Please note that Accelerated Care Plus cannot provide medical advice.
  • Page 6: Electrotherapy Warnings & Precautions

    OMNISTIM ® 500 PRO USER MANUAL ELECTROTHERAPY WARNINGS & PRECAUTIONS CAUTION: Federal law restricts this device for sale or use by, or on the order of, a Practitioner licensed by the laws of the state in which he/she practices to use or order the use of the device. Please note that Accelerated Care Plus cannot provide medical advice.
  • Page 7: Precautions

    Use this device only with the leads, electrodes, and accessories recommended by the manufacturer. Use only ACP specified accessories and/or supplies with ACP devices. Do not use any power cords, or power supplies, other than the ones provided or specified for this device. Use of any other power supply could seriously damage the device and will void the warranty.
  • Page 8 OMNISTIM ® 500 PRO USER MANUAL should be monitored diligently during application. The effect of electrical stimulation may be altered by the presence of these materials on the patient’s skin. • Caution should be used over areas of body where circulation is impaired, or which lack normal sensation. Absent or diminished sensation should be avoided or, if unavoidable, treated with caution.
  • Page 9: The Omnistim ® 500 Pro

    500 Pro inspect the shipping container and contents for any obvious or concealed ® damage. All ACP products are packaged carefully for rapid, safe delivery. We guarantee delivery in perfect condition to the postal or delivery services. However any damage or loss incurred during transportation or delivery is the Postal or Delivery Company’s responsibility.
  • Page 10: Controls And Functions

    OMNISTIM ® 500 PRO USER MANUAL Controls and Functions A. Press button corresponding to the desired functional PROTOCOL group. Chose between PAIN, CIRCULATION, MUSCLE TONE SPASM, ROM, or MUSCLE RE-ED. B. MODIFY TIME/PARAMETER UP or DOWN buttons are used to increase/decrease treatment time or changes parameters in SET mode.
  • Page 11: Factory Settings

    OMNISTIM ® 500 PRO USER MANUAL K. Output for CHANNEL A and HVPC protocols. L. Output for CHANNEL B. M. Increase / decrease OUTPUT A. Press UP arrow button to increase intensity in channel A. Press the DOWN arrow button to decrease intensity in channel A. N.
  • Page 12: Battery Charger / Power Supply Operation

    OMNISTIM ® 500 PRO USER MANUAL Battery Charger / Power Supply Operation Before using the Omnistim ® 500 Pro battery charger/power supply: 1. Verify that rechargeable batteries are installed within the Omnistim 500 Pro battery compartment. ® 2. Check to see that the battery type selector switch located inside the battery compartment has been switched to the rechargeable position.
  • Page 13 OMNISTIM ® 500 PRO USER MANUAL The bar graph on the lower right of the display shows the relative outputs of the two channels primarily with respect to Time On and Time Off and Vector operation. The numeric displays on the lower left show the output intensities into a 500-ohm load.
  • Page 14: Treatment Guidelines

    OMNISTIM ® 500 PRO USER MANUAL TREATMENT GUIDELINES Introduction to Medium Frequency Currents Medium frequency (MF) currents may be described as electrical currents applied to the body for therapeutic purposes, which fall in the range of 1000 to 10,000 cycles per second (Hz). This is in contrast to low frequency currents (0.1 to 1000 Hz) such as LVPC, HVPC, and high frequency currents (1 million Hz and beyond), which include ultrasound, shortwave and microwave diathermy.
  • Page 15: Electrode Application Techniques

    OMNISTIM ® 500 PRO USER MANUAL Electrode Application Techniques The following electrode placement diagrams are a theoretical representation of treatment set-ups using the Omnistim ® 500 Pro. Monopolar, bipolar and quadripolar techniques are illustrated. Electrode placement is dependent on the etiology of the condition. Monopolar (Mono-Polar) Technique This technique may use two electrodes of different sizes.
  • Page 16: Treatment Preparation

    ACP Reusable Electrodes Remove the electrodes from their foil packaging. Cleanse the skin, and then apply the electrodes over the treatment site points according to the electrode placements techniques described in this manual.
  • Page 17: Infection Control Equipment And Principles Of Use

    After each use, clean common contact surfaces, such as control panel and lead wires with ACP germicidal wipes. • With a second ACP germicidal cloth, wipe again leaving surfaces wet for at least 5 minutes. Allow the surface to air dry before patient use. •...
  • Page 18: Use Of Barriers - Intermediate Level Disinfection

    OMNISTIM ® 500 PRO USER MANUAL Use of Barriers – Intermediate Level Disinfection The use of an all-purpose barrier film provides surface protection from cross-contamination resulting from a variety of applications. This precaution should be used whenever dealing with non-intact skin or the chance of coming in contact with bodily fluids.
  • Page 19: Modes Of Operaton

    MODES OF OPERATON: Protocol Reference Sheets Pain Control PROTOCOL / CLINICAL STIMULATION PARAMETERS MECHANISM OF ACTION APPLICATION TECHNIQUE OPERATIONAL SEQUENCE INDICATION • Press PAIN button until screen reads "IFC SENSORY". Sensory stimulation activates A-beta fibers Target tissue - superficial and deep. Bilateral, •...
  • Page 20: Circulation

    Pain Control (cont.) PROTOCOL / CLINICAL STIMULATION PARAMETERS MECHANISM OF ACTION APPLICATION TECHNIQUE OPERATIONAL SEQUENCE INDICATION • Press PAIN button until screen reads "IFC SENSORY MOTOR". Target tissue - superficial and deep. Bipolar IFC SENSORY MOTOR Combines sensory and motor stimulation. •...
  • Page 21: Muscle Tone Spasm

    Muscle Tone Spasm PROTOCOL / CLINICAL STIMULATION PARAMETERS MECHANISM OF ACTION APPLICATION TECHNIQUE OPERATIONAL SEQUENCE INDICATION • Press MUSCLE TONE SPASM button until screen reads Blocks muscle tone by causing a temporary "MOTOR NERVE BLOCK". Target tissue - superficial and deep. Bipolar block of the motor nerve for the muscle in MOTOR NERVE BLOCK placement over local nerve and spastic muscle;...
  • Page 22: Omnistim ® 500 Pro Program Menu

    - 18 - OMNISTIM ® 500 PRO USER MANUAL OMNISTIM ® 500 PRO PROGRAM MENU Pain Control The following protocols are found by pressing the PAIN protocol button. The first protocol displayed is IFC SENSORY. Other protocols follow, in the sequence presented below, by continuously pressing the PAIN button. A.
  • Page 23 OMNISTIM ® 500 PRO USER MANUAL - 19 - C. IFC MOTOR: This program is used to provide symptomatic relief of superficial and deep pain with inflammation, and pain of generalized or multi-segmental nature. Bilateral placement over local and distal acu trigger point. Quadripolar placement over area of local pain, or at spinal segment.
  • Page 24 - 20 - OMNISTIM ® 500 PRO USER MANUAL E. IFC MOTOR SENSORY: Symptomatic relief of superficial pain and deep pain with inflammation, and pain of local, generalized, single or multi-segmental nature. Bipolar placement over local and distal acu trigger points; quadripolar placement over area of local pain, or at spinal segment.
  • Page 25 OMNISTIM ® 500 PRO USER MANUAL - 21 - F. IFC SENSORY MOTOR: Symptomatic relief of superficial pain and pain with inflammation, pain of local generalized single or multi-segmental nature. Bipolar placement over local and distal acu trigger points; quadripolar placement over area of local pain, or at spinal segment.
  • Page 26: Circulation

    - 22 - OMNISTIM ® 500 PRO USER MANUAL H. COMBO HVPC SENSORY: Symptomatic relief of superficial and deep pain from localized dermatome or segmental origin. Bipolar application through the ultrasound transducer at the painful area and over the involved spinal segments or trigger points.
  • Page 27: Muscle Tone Spasm

    OMNISTIM ® 500 PRO USER MANUAL - 23 - B. MFAC MUSCLE PUMP: Increase circulation, venous and lymphatic return through muscle pump. This program targets superficial and deep muscle groups and large joints. Bilateral set-up over agonist and antagonist muscles for target joint.
  • Page 28 - 24 - OMNISTIM ® 500 PRO USER MANUAL B. MFAC TONE-SPASM: Relaxation of muscle spasm. Target is superficial and deep muscle groups. Bipolar set-up over agonist and antagonist muscles for target muscle. Intensity should be set to elicit a grade 2-3 muscle contraction. Activation of muscle with electrical stimulation with a 1:1 ratio of “ON/OFF”...
  • Page 29: Range Of Motion (Rom)

    OMNISTIM ® 500 PRO USER MANUAL - 25 - Range of Motion (ROM) The following protocol is found by pressing the ROM protocol button. The protocol displayed is MFAC INCREASE ROM. A. MFAC INCREASE ROM: Provides e-stim-assisted passive or active assisted ROM at a joint. Target tissue is the superficial and/or deep muscle groups.
  • Page 30: Muscle Re-Education

    - 26 - OMNISTIM ® 500 PRO USER MANUAL Muscle Re-Education The following protocols are found by pressing the MUSCLE RE-ED protocol button. The first protocol displayed is MFAC SURFACE DEEP MUSCLE. Other protocols follow, in the sequence presented below, by continuously pressing the MUSCLE RE-ED button.
  • Page 31: Stimulation Therapy Modes

    OMNISTIM ® 500 PRO USER MANUAL - 27 - STIMULATION THERAPY MODES Interferential Current Therapy (IFC) The new Webster Encyclopedia Dictionary of RATE SCAN ON OR OFF the English Language defines interference as 2500 or 5000 Hz Pulsed at 100Hz “the mutual action of waves of any kind (water, 2500 or 5000 Hz sound, heat or light) upon each other, by which...
  • Page 32 - 28 - OMNISTIM ® 500 PRO USER MANUAL 500 Pro Sport when in the full field mode of operation. The highest intensity field is obtained in the deep tissue at bisecting angles to the out-of-phase electrodes. This technique offers three stimulation fields. 2.
  • Page 33: Medium Frequency Alternating Current (Mfac)

    Gradually increase intensity to maximum patient tolerance during each contraction. The intensity should be increased to produce at least 50 to 80% of Maximum Voluntary Contraction (MVC). Place ACP Reusable Electrodes in a bipolar or quadripolar pattern on the muscle(s) being stimulated. The treatment should be approximately 15 minutes duration 3 to 4 times a week.
  • Page 34: Low Voltage Pulsed Current (Lvpc)

    - 30 - OMNISTIM ® 500 PRO USER MANUAL ON - OFF TIME: On time adjustable from 0 – 30 seconds, Off time adjustable from 0 - 199 seconds. CHANNEL TIMING: Simultaneous, alternate or delayed channels. DELAY MODE: Adjustable from 0-9.9 seconds. AUTO INTENSITY: Adjusts the output during treatment automatically from 0 to 20% user programmable.
  • Page 35: Troubleshooting

    500 PRO USER MANUAL - 31 - TROUBLESHOOTING The following table lists machine problem symptoms and possible areas to check for the problem causes. If these suggested measures do not correct the machine malfunction, call your ACP Customer Support representative. PROBLEM CAUSE REMEDY •...
  • Page 36 - 32 - OMNISTIM ® 500 PRO USER MANUAL INSPECT BATTERY CONTACTS / VERIFY BATTERY SWITCH SET TO RECHARGEABLE 1. Remove batteries if they are installed. 2. Inspect the battery contacts for any corrosion or discoloration. If corrosion or discoloration is found, perform the following steps to clean the metal contacts: •...
  • Page 37 OMNISTIM ® 500 PRO USER MANUAL - 33 - Press power supply switch Figure 5a Figure 5b 4. Verify the CHARGE light is on or blinking (Figure 6). 5. Power on the stimulator and verify that you hear a click of the safety circuit relay energizing. Charge light For reference only: Charge light solid - charging in...
  • Page 38: Service Center

    Service Center For repair or service of ACP Products and accessories, please call (800) 350-1100 and follow the prompts. Normal hours of operation are 6:00am to 5:00pm Pacific Standard Time. After hours, please leave a message and a technician will return your call during the next scheduled workday.
  • Page 39: Technical Specifications

    OMNISTIM ® 500 PRO USER MANUAL - 35 - TECHNICAL SPECIFICATIONS GENERAL: Dimensions: 12" (30cm) D x 6.5" (16.5cm) W x 3" (7.6cm) H 3lbs. 14oz. (1.75 kgs) Weight (including batteries): 120/240VAC; 50/60Hz; 50W Operating Power: 4 x 1.5VDC “D” cell alkaline or rechargeable batteries. New alkaline batteries operate the system for 40 hours at full output and over 100 hours at normal settings.
  • Page 40 Caution: Federal law restricts this device to sale by or on the order of a physician (or other health practitioner licensed by their State). ACP reserves the right to change technical specifications and product availability without notice. COPYRIGHT © 2004 - 2018, ACCELERATED CARE PLUS CORP., ALL RIGHTS RESERVED...
  • Page 41: Omnistim ® 500 Pro Standard And Optional Accessories

    OMNISTIM ® 500 PRO USER MANUAL - 37 - OMNISTIM ® 500 PRO STANDARD AND OPTIONAL ACCESSORIES ITEM ITEM NO. DESCRIPTION OMNISTIM ® 500 PRO MULTIMODALITY MICROPROCESSER CONTROLLED TREATMENT SYSTEM 2 channels of programmable stimulation with 100500C IFC Frequency Difference Interferential, MFAC (Russian style NMES), High Volt Pulsed Current (HVPC) and Low Volt Pulsed Current (LVPC).
  • Page 42: Electrodes

    - 38 - OMNISTIM ® 500 PRO USER MANUAL Electrodes ITEM ITEM NO. DESCRIPTION MULTI-USE ELECTRODES 2x2 Multi-use E-stim Electrodes 38155 (4ea/pkg, 10pkg/bx) 2x4 Multi-use E-stim Electrodes 61227 (4ea/pkg, 10pkg/bx) 3x5 Multi-use E-stim Electrode 26854 (2ea/pkg, 10pkg/bx) SINGLE-USE WOUND CARE ELECTRODE 4x4 Single-use Non-Gelled Electrode 40944 (25ea/bx)
  • Page 43: Standard Limited Product Warranty

    Standard Limited Product Warranty. Buyer is responsible for shipping cost associated with sending the Equipment to the ACP Service Center. ACP shall ship Equipment to Buyer after repair at no cost to the Buyer provided repair is deemed to be under warranty.
  • Page 44 ACP is not responsible for any loss or damage to the Equipment prior to receipt at the ACP Service Center. Equipment returned for warranty service must be shipped complete with all accessories (except for manuals), in its original packing or equivalent so as not to be damaged while in transit.

Table of Contents