NEC Express 5800 Series User Manual page 95

Smart storage administrator
Hide thumbs Also See for Express 5800 Series:
Table of Contents

Advertisement

Error code
Error message
Invalid Drive Cache setting. Valid options are
3028
ENABLE and DISABLE.
Invalid or out of order Command
3029
Invalid or missing Array for Reconfigure
3030
Invalid or missing Filename for Firmware
3031
Update
Firmware Update Failed
3032
This controller has been configured with a
3033
more recent version of software. To prevent
data loss, configuration changes to this
controller are not allowed. Please upgrade
to the latest version to be able to continue
to configure this controller.
Operations on this Array are temporarily
3034
unavailable while the Array is transforming.
Invalid value for NoBatteryWriteCache
3035
Cannot delete Logical Drive
3036
The SplitMirror command is not valid for the
3038
specified Array
This command is only available when
3046
running offline
Caching Volume parameters are not valid for
3047
a data Volume
Invalid Spare Mode
3048
Encryption Login Failed
3049
Encryption Login command is not available
3050
The Encryption command is not available
3051
The Zeroize command failed
3052
The Firmware Lock/Unlock failed
3053
Unable to change the Key Manager Mode
3054
Unable to set the Key Encrypting Key
3055
Unable to set the boot password
3056
Unable to set the boot password state
3057
The controller does not support encryption
3058
Controller Encryption is disabled
3059
Comment or clarification
Verify the ordering of the commands in the input
configuration file.
Expecting a valid array in Reconfigure mode
The firmware filename supplied is not a valid
filename.
The firmware flash operation on the controller failed.
Some changes to SOULAPI are not backward-
compatible. This check prevents the use of an older
version of software on a controller configured with a
newer version, possibly overriding changes and
destroying data.
The user requested too many simultaneous
changes. For example, the user added new disks to
an array (expand array) and changed the size or
RAID level of logical volumes on the array. The
solution is for the user to wait until the array
transformation is complete.
A problem exists with the NOBATTERYWRITECACHE
command. Check the supplied argument. Not all
controllers support this operation.
A problem occurred during the attempt to delete the
specified logical drive. The drive may be in use by
the OS, it may not exist, or it may not be the last
logical drive on the array.
The operation is not available. Older array
controllers/firmware may not support this command.
The operation requested cannot be performed
online. Boot to offline SSA Scripting and supply the -
offline parameter.
The parameters supplied are not applicable or valid.
The controller firmware returned an error when
attempting to set zeroize the encryption
configuration.
The controller firmware returned an error when
attempting to lock or unlock the firmware.
The controller firmware returned an error when
attempting to change the key manager mode.
The controller firmware returned an error when
attempting to set Key Encrypting Key name.
The controller firmware returned an error when
attempting to set the boot password.
The controller firmware returned an error when
attempting to set the boot password state.
An attempt was made to execute an encryption
command on a controller which does not support
encryption.
An attempt was made to execute an encryption
SSA Scripting 95

Advertisement

Table of Contents
loading

Table of Contents