Error code
Error message
Invalid Option
3000
Invalid Command
3001
Command Failed
3002
License Key Delete Failed
3003
Invalid Sector Size
3004
Cannot delete Array
3005
Invalid Number of Parity Groups
3006
Chassis name is too long
3007
Chassis name is already in use
3008
Auto Configure failed
3009
Cannot extend logical drive, not enough free
3010
space for the requested size
Cannot extend logical drive, requested size
3011
is too small
Cannot specify both SIZE and SHRINKSIZE
3012
Cannot shrink Array
3013
Cannot move Array
3014
Invalid operation - Advanced Pack support
3015
required
Spare drives cannot be specified by a count
3016
in Reconfigure mode
Disk drives cannot be specified by a count in
3017
Reconfigure mode
Invalid number of physical disks
3018
Cannot create Array - no physical disks
3019
specified
SSP must be enabled in order to perform
3020
this operation
Invalid connection name
3021
The connectionname cannot be removed
3022
when the hostmode has a non-default value.
Invalid Host Mode
3023
Invalid Adapter ID
3024
This controller does not have host mode
3025
modification capability
You need to have administrator rights to
3026
continue
Another instance of SSA is already running
3027
(possibly a service). Please terminate the
SSA application before running SSA
scripting.
Comment or clarification
The value of the option supplied to this parameter is
invalid.
The command is invalid.
The controller returned an error for a command.
SSA is unable to delete the license key.
Another controller is already using the entered
chassis name.
The Auto Configure mode was unable to complete
auto configuration.
The input file cannot specify both a SIZE and
SHRINKSIZE parameter.
The array shrink operation was not successful.
The array move operation was not successful.
The requested operation requires a valid license key
to be entered.
When in Reconfigure mode, the requested spare
drives must be specified by their addresses. A
simple count cannot be used.
When in Reconfigure mode, the requested data
drives must be specified by their addresses. A
simple count cannot be used.
SSA cannot create an array unless physical disks are
specified in the input file DRIVE parameter.
For the specified operation, SSA requires SSP to be
supported and enabled.
SSA Scripting 94