1. General Operation:
When the system is operating, one of the three displays may be shown. Pressing next will alternate
between displays. One of the displays is always the current time of day. The second display shows
the current treated water flow rate through the system in Gallons Per Minute (gpm). NOTE: the
Gallons Per Minute display will always show 0.0 because there is no meter to detect flow in the
IBW/IMBW. The third display shows the current days remaining before regeneration.
The user can scroll between the displays as desired.
If the system has called for a regeneration that will occur at the preset time of regeneration, the words
REGEN TODAY will appear on the display.
2. Regeneration Mode:
Typically a system is set to regenerate at a time of no water use. If
there is a demand for water when the system is regenerating,
untreated water will be delivered. When the system begins to
regenerate, the display will change to include information about the
step of the regeneration process and the time remaining for that
step to be completed. The system runs through the steps
automatically and will reset itself to provide treated water when the
regeneration has been completed.
3. Manual Regeneration:
Sometimes there is a need to regenerate before the control valve calls for it. This may be needed if a
period of heavy water use is anticipated or when experiencing excessive pressure drop.
To initiate a manual regeneration at the
preset delayed regeneration time, press
and release regen. The words "REGEN
TODAY" will flash on the display to
indicate that the system will regenerate at
the preset delayed regeneration time.
If you pressed the regen button in error,
pressing the button again will cancel the
command.
To initiate an immediate manual regeneration, press and hold the regen button for
three seconds. The system will begin to regenerate immediately. This command
cannot be cancelled.
4. Power Loss:
If the power goes out for less than two hours, the system will
automatically reset itself. If an extended power outage
occurs, the time of day will flash on and off which indicated
the time of day should be reset. The system will remember
all other settings.
Error Message: If the word "ERROR" and a number are
alternately flashing on the display, record the number and contract the dealer for help. This indicates
that the control valve was not able to function properly.