First Sales NBW10 Installation Instructions And Owner's Manual

Backwashing filter system nbw series; nebw series

Advertisement

Quick Links

Installation Instructions and Owner's Manual
NBW & NEBW Series
Backwashing Filter System
First Sales, LLC
12630 US Highway 33 N
Churubusco, IN 46723
Phone (260) 693-1972
Fax (260) 693-0602
NBW-NEBW Series Installation Manual 170623.docx

Advertisement

Table of Contents
loading

Summary of Contents for First Sales NBW10

  • Page 1 Installation Instructions and Owner’s Manual NBW & NEBW Series Backwashing Filter System First Sales, LLC 12630 US Highway 33 N Churubusco, IN 46723 Phone (260) 693-1972 Fax (260) 693-0602 NBW-NEBW Series Installation Manual 170623.docx...
  • Page 2: Table Of Contents

    Table of Contents Pre-installation Instructions Page 2 General Installation Page 4 Installation Instructions Page 5 NBW Time Clock Timer Setting Page 7 NEBW Electronic Display Operation Page 8 NEBW Electronic Programming Page 9 Specifications Page 11 Component Parts Breakdown & List Page 12 NBW Control Valve Breakdown Page 13...
  • Page 3: Pre-Installation Instructions

    Successful Application Any filter media may have specific limitations and/or requirements for successful application. A water sample should be submitted to First Sales for analysis and recommendation by Customer Service. Time of Backwash Periodically the control valve will go through a backwash cycle. This cycle is factory preset to 12:00 A.M.
  • Page 4 Pre-Installation Instructions Water Supply This filter will function properly when the water supply is furnished by a jet pump, submersible pump, variable speed (constant pressure) pump or community water supply. As with all other filter systems, however, it is imperative that the well pump provides enough flow rate for the filter to adequately backwash. In order to ensure sufficient backwash flow rate the following pumping rate test should be performed prior to installing the NBW/NEBW.
  • Page 5: General Installation

    General Installation GENERAL INSTALLATION & SERVICE WARNINGS The water conditioner is not designed to support the weight of plumbing. Do not use Vaseline, oils, other hydrocarbon lubricants or spray silicone anywhere. A silicone lubricant may be used on black “O” Rings. This will allow ease of installation and decrease chance of rolling from the bypass and tank connections.
  • Page 6: Installation Instructions

    Installation Instructions STEP 1: Carefully remove all components from packaging. DO NOT DISCARD PACKAGING until all backwash system components and fittings have been located. STEP 2: Place unit at desired installation position. Be sure the location is within 15 feet of a drain that is lower than the control valve and near a non-switched electrical outlet.
  • Page 7 Installation Instructions (cont.) STEP 9: Cut main supply line as required to fit plumbing to inlet and outlet of bypass valve. STEP 10: Attach plumbing. DO NOT apply heat to any fitting connected to bypass valve or control valve, as damage may result to internal parts or connecting adapters. MAKE CERTAIN WATER ENTERS THROUGH INLET AND DISCHARGES THROUGH OUTLET (See figure 2).
  • Page 8: Nbw Time Clock Timer Setting

    NBW Time Clock Setting Instructions FIGURE 5: Front of Time Clock Timer Assembly How to set Time of Day: 1. Press and hold the red button to disengage the 24 hour gear. 2. Turn the large 24 hour gear until the actual time of day is at the time of day arrow. 3.
  • Page 9: Nebw Electronic Display Operation

    NEBW Electronic Display Operation Advance Button FIGURE 6: Front of Electronic Meter Timer Assembly SET BUTTON 1. Press and hold Set Button for 5 seconds to enter Programming Mode. 2. When valve is in Programming Mode, press Set Button to confirm setting and advance to next menu option.
  • Page 10: Nebw Electronic Programming

    NEBW Electronic Programming Enter Programming Mode: Press and Hold the SET Button for 5 seconds. Use Up Button to set current hour Use Up Button to set current minute Use Up Button to set AM/PM DO NOT change this setting Exit Programming Mode...
  • Page 11 This page intentionally left blank...
  • Page 12: Specifications

    Specifications Description NBW10 NBW15 NBW20 Filter Media Volume, cu. ft. Gravel Underbed, lbs. Operating Flow Rate, gpm Continuous (no duration limit, 5 gpm/ft Service (intermittent flow up to 10 gpm/ft Peak (10 mins. or less, 15 gpm/ft Backwash Flow Rate...
  • Page 13: Component Parts Breakdown & List

    Component Parts Breakdown & List Unit Description Ref # NBW10 NBW15 NBW20 NEBW10-S NEBW15-S NEBW20-S NBW10/15 NBW10/15 Timeclock Valve NBW20 Vlv Vlv Assy Vlv Assy w/bypass Assy w/BP w/BP w/BP NEBW10/15 NEBW10/15 NEBW20 Electronic Metered Vlv Assy Vlv Assy Vlv Assy...
  • Page 14: Nbw Control Valve Breakdown

    NBW Time Clock Control Valve Breakdown...
  • Page 15: Nbw Control Valve Parts List

    Motor, 120v/60hz, 1/30 RPM 13304 O-Ring, Distributor, -121 12281 O-Ring, Tank, -338 12092 Flow Control Washer, 5.0 GPM (NBW10, NBW15) 12408 Flow Control Washer, 7.0 GPM (NBW20) NE-DRAIN ELB Drain Elbow, Quick Connect x ½” barbed NE-DRAIN CLIP Quick Release Clip, Drain Elbow...
  • Page 16: Nebw Control Valve Breakdown

    NEBW Electronic Control Valve Breakdown...
  • Page 17: Nebw Control Valve Parts List

    NEBW Electronic Control Valve Parts List REF # Part Number Description NE-PH Power head, Metered NE-FC Front Panel and Circuit Board Assembly 60102-00 Piston Assembly 60125 Seal and Spacer Kit NE-BW HOUSING Drain Housing, Blank DLFC EM-1 Meter Module (includes cable) 60040SS ¾”...
  • Page 18: Troubleshooting

    Troubleshooting PROBLEM CAUSES SOLUTIONS 1) Check timer motor and replace if faulty 2) Ensure uninterrupted power supply 3) Check Backwash frequency setup 4) Verify sediment being removed is less A) Filter not dense than the filter media and install a backwashing “Spin-Down”...
  • Page 19 Troubleshooting (cont.) PROBLEM CAUSES SOLUTIONS Loss of electrical power during regeneration 1) Ensure electrical outlet is functioning Continuous flow of B) Debris in control 2) Disassemble and clean control valve water to drain valve 3) Replace seals and/or piston C) Internal leak in 4) Replace faulty drive motor control valve D) Timer motor faulty...
  • Page 20: Ten Year Limited Warranty

    Ten Year Limited Warranty WARRANTY – First Sales, LLC. warrants this water conditioner against any defects that are due to faulty material or workmanship during the warranty period. This warranty does not include damage to the product resulting from accident, neglect, misuse, misapplication, alteration, installation or operation contrary to printed instructions, or damage caused by freezing, fire, flood, or Acts of God.