Gas Connection; Gas Categories; Connection Pipe Requirements - CAN FL1400 Installation, Use And Maintenance Instructions

Fl series
Table of Contents

Advertisement

GAS HOB UNITS COMBINED WITH RECESSED SINK ▪

GAS CONNECTION

ATTENTION!
Before performing the connection, make sure that the gas system and the installation rooms
are suitable for the purpose and comply with standards in force in the Country of installation.
Refer to the specific technical standards regarding conformity of gas systems (LPG) for the
household (UNI CIG 7131 e 7129), nautical ( UNI EN ISO 10239) and recreational vehicles
sectors (UNI EN 1949).
Before connecting gas, check that:
the supply line is free from obstructions and has sufficient flow rate to guarantee correct operation
of the appliance;
there is a suitable pressure regulator/reducer compliant with the gas categories used on the appliance
immediately downstream of the gas cylinder or container feeding the system;
a gas shut-off valve or a valve disconnecting the system is installed on the supply line, downstream of
the regulator and immediately upstream of the appliance intended to connect, in a place which can
easily be accessed and inspected. (Please note: this valve must always be shut during installation and
maintenance on the appliance).
ATTENTION!
Make sure that the type of gas which will feed the appliance is among those allowed and listed
in the instruction booklet (see paragraph "Gas categories").

GAS CATEGORIES

The appliance was designed for correct operation only with the types of gas categories and operating
pressures listed below:
gas category and country of
destination
I3B/P (30)
AT-BE-DE-DK-FI-GB-NL-NO-PT-SE-SI
I3+ (28-30/37)
BE-CH-ES-FR-GB-IE-IT-PT-SI

CONNECTION PIPE REQUIREMENTS

ATTENTION!
The appliance must be connected to the gas pipeline by means of a suitable connection pipe
making use of certified sealed fittings the type most suitable for the application.
It is possible to use flexible connection hoses. They must:
always be able to be inspected,
be protected against contact with hot parts (e.g. burner cups),
be protected from the movable parts of the recessing (drawers, doors, etc.),
have a length which complies with the technical standards for each sector of reference.
Avoid any type of mechanical stress on the flexible hoses during installation and use (protection against
traction, twisting, crushing, etc.).
ATTENTION!
Perform maintenance and periodically replace the flexible hose within the expiration date
written on the sheath. Do not use expired or damaged flexible hoses by any means.
20
name of gas
Butane (G30)
Propane (G31)
Butane (G30)
Propane (G31)
FL series
operating pressure
30 mbar
30 mbar
28 - 30 mbar
37 mbar

Advertisement

Table of Contents
loading

Table of Contents