Samsung CLX-6250FX Service Manual page 43

Digital color laser mfp
Hide thumbs Also See for CLX-6250FX:
Table of Contents

Advertisement

2.4.2.4 Fuser Drive Board
The FDB (Fuser Drive Board) controls 2 halogen lamps in the fuser unit using control signals which are
provided from the ENGINE PBA and supplies AC power to the SMPS. Both V1/V2 FDBs provide max.
1500W output power.
2
2
1
1
Fuse
Varistor
■ Connection
1
INLET AC
2
FUSER CONTROL (from Main board)
3
FUSER AC (to Fuser lamp)
4
SMPS AC ( to SMPS)
■ Specification
Input Voltage
(Range)
Input Current
Output Power
Phase Detect
Protection
Service Manual
Product Specification and feature
Triac
Photo Triac
V1
AC 110V
(90 ~ 135V)
20A
Max. 1300W
Not support
Relay Control Signal
2-34
HEAT SINK
V2
AC 220V
(180 ~ 270V)
10A
Max. 1300W
3
3
4
4
Samsung Electronics

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Clx-6220fx

Table of Contents