● Code
01-017
● Symptom
When the tray limit is reached, the out-bin full sensor is on for 600ms.
● Possible Cause
1. Check the Out-Bin Full Sensor.
2. Check if the UI message is changed by the Out-Bin Full Sensor operation.
3. Check the Out-Bin Full Sensor Harness and Connector.
● Troubleshooting method
1. Check the BIN_FULL_SENSOR (picture'1' below) by pushing the trigger (picture'2' below) beneath the SCAN_
ASSY.
Check if the UI message is changed by the Out-Bin Full Sensor operation
2. Check if the Harness is defective.
Check if the connector is connected properly.
3. Replace the Main PBA or the Scan_Joint PBA or the Panel PBA.
4. Enter the EDC mode and follow the below sequence after the repair is done.
( EDC Mode → Test Routines → 101-Clutch → 0190-OutBin Full → Start → Status check → Stop )
Service Manual
Alignment & Troubleshooting
● Error message
Output bin Full
Output bin Full.
Remove printed paper
1
2
4-38
Samsung Electronics