  • Page 1 GoboLED 80 D AL2502 Manuale di istruzioni Instructions manual...
  • Page 2: Table Of Contents

    INDEX 1.0 Introduction ..........................20 1.1 Safety information...............................20 1.1.1 Protecting against electric shock ..........................20 1.1.2 Installation ................................20 1.1.3 Protection against burns and fire ...........................20 1.1.4 Weather protection..............................20 1.1.5 Forced ventilation ..............................20 1.2 Compliance ................................20 2.0 Size ...............................21 3.0 Packaging and transport ......................21 3.1 Packaging ...................................21 3.2 Transport ..................................21 4.0 Installation ...........................22...
  • Page 3: Introduction

    1.0 Introduction 1.1 Safety information Warning! This unit is suitable for professional use only, not for domestic use. 1.1.1 Protecting against electric shock • Disconnect the unit from mains supply before servicing it or performing any other action. • Always ground/earth the unit electrically. •...
  • Page 4: Size

    • Griven S.r.l. will accept claims for broken or missing goods only within seven days of receipt of the goods. • Returns of equipment will not be accepted without prior authorization granted by Griven S.r.l. and if not duly ac- companied by relevant shipping documents.
  • Page 5: Installation

    4.0 Installation 4.1 Fixing The unit can be used both rested on floor and fixed onto a structure. The unit can operate in any position. Use the holes “4” Ø10.5 (0.4”) in the bracket to fix the unit. 4.2 Adjusting light beam direction A.
  • Page 6: Connection To Mains Power

    4.3 Connection to mains power The unit can operate with voltage from 100 to 240Vac and with frequency of 50 and 60Hz. It is not necessary to effect any setup procedures. The fixture will automatically adjust its operation to suit any fre- quency or voltage within this range.
  • Page 7: Connection To Dmx Signal

    C. Close the unit again by tighten the screw “6” previously re- moved. 4.4 Connection to DMX signal The DMX signal is to be connected by using a shielded cable designed for devices RS-485. The unit is fitted with internal pins for the connection of the of the DMX signal cable, as shown in the following pictures.
  • Page 8: Gobo Installation

    Warning! All data wires must be isolated one from another, from the shield and from the metal housing of the connectors. Pin number 1 of the housing is not to be connected to the electric ground of the unit. Insert a 120 Ω resistor connected to Data+ and Data- in the last unit. C.
  • Page 9 C. Insert the gobo in the gear “13”. D. Insert the rubber gobo holder “14”. E. Block the gobo by using the spring “15”. F. Close the unit again by tighten the screw “11” previously re- moved. English...
  • Page 10: Focus And Zoom

    4.6 Focus and zoom A. Untighten the screw “11” and remove the lower cover. B. Move the lenses on order to adjust the beam angle and then tighten the knob “12”. C. Close the unit again by tighten the screw “11” previously removed.
  • Page 11: Use Of The Unit

    5.0 Use of the unit 5.1 Setting operating mode By the dip-switch set it is possible to select one of the following operating modes: • using DMX512 signal control mode Each fixture is controlled from DMX512 signal control. • MASTER-SLAVE or AUTOMATIC mode The projector operates independently, without DMX512 signal control.
  • Page 12: Dmx Functions

    Example Unit with address 005 (dip-switch n°1 and 3= ON) and CH MODE = OFF 1 2 3 4 5 6 7 8 9 10 11 12 Example Unit with address 007 (dip-switch n°1, 2 and 3 = ON) and CH MODE = ON 1 2 3 4 5 6 7 8 9 10 11 12 5.3 DMX functions Attention!
  • Page 13: Dmx Functions In Ch Mode = 2

    5.3.2 DMX functions in CH mode = 2 Channel Function Value Description 0-15 No rotation 16-150 Proportional control 0-100% of the clockwise rotation Gobo Rotation 151-160 No rotation 161-255 Proportional control 0-100% of the counterclockwise rotation No effect Indexing 8-248 360°...
  • Page 14: Master-Slave And Automatic Function

    6.0 Master-Slave and Automatic function Goboled 80 can operate without DMX signal (in AUTOMATIC mode) and can be set so that a single MASTER unit will command a series of SLAVE units. This function is particularly useful when more units are desired to execute the same programme in synchrony.
  • Page 15: Slave Configuration

    Dip-switch Effect Clockwise rotation speed 1 Clockwise rotation speed 2 Clockwise rotation speed 3 Clockwise rotation speed 4 Counterclockwise rotation speed 1 Counterclockwise rotation speed 2 Counterclockwise rotation speed 3 Counterclockwise rotation speed 4 Random rotation Warning! Set the dip-switches 1-9 to OFF to stop the rotating movement. 6.2 SLAVE configuration To set up the unit as SLAVE adjust all the dip-switches to OFF.
  • Page 16: Thermal Protection

    • Check that the unit is not damaged mechanically. Replace those components which have got deteriorated. 9.0 Spare parts All components of the unit are available as spare parts at Griven dealers. Exploded views, wiring diagrams, electronic layouts and advertising brochures are available on request.
  • Page 17: Troubleshooting

    10.0 Troubleshooting Inconvenience Possibile Cause Action Check that the power supply cable is connected and the Unit not powered up. unit is powered. The fixture will not turn Out of order PCB Check the PCB functions. Incorrect DMX cable Check connections and wires. Rectify inefficient connec- connection.
  • Page 18: Disposal

    11.0 Disposal The European Directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE), requires that old lighting fixtures must not be disposed of the normal unsorted municipal waste stream. Old appliances must be collected separately in order to optimise the recovery and recycling of the materials they contain and reduce the impact on human health and the environment.