    Operating Instructions Contemporary and Stylish B600 B900 B605 B905 Keep instructions in a safe place for future reference DO NOT DISCARD THESE INSTRUCTIONS Pecan Engineering Pty Limited proudly supports the activities of Landcare Australia through its membership of the AHHA...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS USER INSTRUCTIONS USER INSTRUCTIONS INTRODUCTION …………………………………………… 2 1. INTRODUCTION USING APPLIANCE FOR FIRST TIME ……………… 3 RECOMMENDED FUELS ……………………………….. 3 Before use of this appliance please read these instructions LIGHTING THE FIRE ……………………………………… 3 fully. RUNNING THE APPLIANCE ………………………….. 4 WARNING: ANY MODIFICATION OF THE APPLIANCE THAT BURNING TIPS …………………………………………….
  • Page 3: Using Appliance For First Time

    Plug the lead from the rear of the heater into a power-point.  B600 & B900 models have an override switch on the rear Poor quality timber: panel next to where the power lead exists the heater base. Causes low combustion efficiency This must be switched on for the fan to run.
  • Page 4: Running The Appliance

     Reload with more wood Add larger pieces of wood. Too many logs may smother the fire. 1) Open air slide before opening door.  Close the door. 2) Rake / break up any existing coals.  Do not leave fire unattended while door is not closed. 3) Load the wood with the length orientated front to back.
  • Page 5: Ash Removal

    Factors affecting the flue draught include: 10. CLEANING THE FLUE  Insufficient flue height   Check inside of flue prior to each season for any build- Trees or other buildings nearby causing turbulence up of creosote (wood tar). To do this: ...
  • Page 6: Troubleshooting Tips

    Contact the installer should this happen. B600 & B605 – Brick Layout Trouble starting the fire If all ash has been removed from the firebox, then it can upset the supply of air to the base of the fire.
  • Page 7: Replacement Of Baffle

    3. REMOVING THE DOOR 2. REPLACEMENT OF BAFFLE The 6mm thick steel baffle helps to retain the heat in the To remove the door: firebox by lengthening the path of the flame so that they do 1) Open the door until it rests against the door stop. not go straight up the flue.
  • Page 8: Fitting A New Door Glass

    5. FITTING A NEW DOOR GLASS Glass retainer Door Rope This task may be easier with the door removed from the appliance and laid horizontally on a work-bench. To replace the door glass: Remove the six M6 size Allen key screws securing the glass retainer to the door with the supplied Allen key.
  • Page 9: Changing Fan Controller Frequency

    495mm x 290mm B900 & B905 595mm x 320mm  B600 & B900 Models – located in the base unit, in Door Glass the rear panel on the left hand side, removed via two B600 & B605 483mm x 253mm x 5mm pyro ceramic screws with a M6 Allen key.
  • Page 12 Pecan Engineering Pty Limited 13 Acorn Road, Dry Creek South Australia 5094 T: (08) 8349 8332 | F: (08) 8260 6643 Email info@pecan-eng.com.au...