Troubleshooting Guide
Symptom
Possible Cause
Lights on Control Unit
• Batteries are not inserted
• Check batteries are inserted in the Control Unit observing the
correctly or may be flat.
correct polarity.
don't illuminate when
• Control Unit requires 4 X AA 1.5V Alkaline batteries (not supplied).
turned ON
Low battery warning
• Batteries low.
If red low-battery warning light flashes, replace all batteries as
(red light) on the
soon as possible. If in addition clicking is heard, all batteries must
Control Unit
be replaced immediately.
• Sensor pad is out of order.
• Connect one sensor pad lay the baby on the bed for 1 minute.
False alarm up to 1/2
• Cable is connected to
If the alarm does not activate, the sensor pad is in order. If the alarm
minute from activating
monitor's blocked socket.
activates, disconnect and place the sensor pad aside.
• Connect the other sensor pad and repeat steps above.
• Do not connect any cables to the blocked socket (only to "SENSOR" socket).
False alarm after 1/2
• The mattress is not
• Make sure that the mattress and the sensor pads
minute from activating
touching the sensor pads.
are touching.
• The mattress is raised (there is
• Make sure that there are no objects next to the sensor pads
an object near the sensor pads).
• Placing two sensors next to each
• Connect according to instructions.
other or using one sensor when the
• It is important to use only one sensor pad when the baby is young and is
baby is of crawling age, or using two
not crawling yet.
sensor pads far apart from
• It is important to make sure that two sensor pads are used when the baby is
each other when baby is young and
moving around.
is not crawling yet.
• Make sure the sensors are placed directly underneath the baby's position in
the bed/crib.
• The mattress does not enable
• Place extra plywood under the sensor pad so that the sensor pad and
transfer of baby movements. (a rigid
the mattress will be tightly pressed together (see page 2, section 4).
mattress, a mattress with springs or
a mattress with air pockets).
Delayed alarms
• Performance test is not correct.
• Do not conduct performance test by picking up the baby out of bed
and waiting for the alarm to sound.
while taking the baby
Kindly conduct performance test according to guidance in page 3.
out of the bed
• Perform a test which will detect the source of the movement that the
The alarm does
• Environmental influences
device detects. For example, sources of wind such as: air conditioner, an
not go off within
detected by the sensor
open window or a fan; movements of a baby mobile (which can vibrate
20 seconds when
pads, such as wind, fan, air
even if it's not turned on) walking around the bed area. Solutions:
performing the
conditioner, baby mobile toy,
Eliminate sources of wind, remove the baby mobile etc. After neutralizing
correct
vibrations.
all environmental influences, perform the test again. If even after
performance test
neutralizing all of the environmental influences, the alarm does not go
off within 20 seconds, perform the following:
1. Test the control unit:
- Disconnect all cables from the control unit.
- Turn control unit on (with no cables attached).
- Alarm activation within 20 seconds indicates that the unit is OK –
proceed to the next steps.
- If the alarm does not sound within 20 seconds, stop using the device
and contact your local distributor.
2. Test each sensor pad separately:
- Connect one sensor pad to either "SENSOR" socket on control unit.
- Turn control unit on and take two steps back from the bed.
- Alarm activation within 20 seconds indicates that the sensor is OK –
perform the above procedures with the second sensor pad.
- If the alarm does not sound within 20 seconds, place the sensor pad aside.
Note: If one of the sensor pads is NOT OK, continue using the product
with only the one correctly functioning sensor. If one or both sensors
are NOT OK, contact your local distributor for further guidance.
3. Test two sensor pads together:
- If both sensors were OK in Step 2, connect both sensors to "SENSOR"
sockets on the control unit.
- Turn control unit on and take two steps back from the bed.
- Alarm activation within 20 seconds indicates that the sensors are OK –
continue using the product.
- If the alarm does not sound within 20 seconds, connect one sensor only and
continue using the product. Contact your local distributor for further guidance.
4
Solution
Technical Specifications
Powered by 4 size AA, 1.5 volt batteries.
Power consumption approx. 1mA.
Battery life approx. 6 months using alkaline batteries.
Alarm volume typically 85dB SPL at distance of
3.5 feet.
Size of sensor pad is
216 mm.
Contents
• Control Unit
• Control Unit Holder
• Optional hanging hook
• 2 Sensor pads
• 2 Cable Ties
• User guide
Please note that the batteries are not supplied.
Caring for your Babysense
Babysense requires no special treatment beyond
replacing batteries when the battery indicator light
goes on. The sensor pads and control unit may be
wiped with a damp cloth.
Batteries should be removed and the device stored in
a dry shaded place when not in use.
It is recommended to replace sensors
every two years
Other phenomena, symptoms, malfunctions – if you cannot find and solve the
problem, please contact us at www.babysensellc.com
V.BS5S.3.EN.4.15
Limited 1 Year warranty
This product is warranted to be free from defects in
material and workmanship for a period of (1) year
from the date of purchase, except as noted below.
BabySense LLC will repair or replace this product, at
our option, at no cost. This warranty does not apply to
product that has been damaged as a result of
improper maintenance or other misuse. This warranty
is also void if the owner repairs or modifies the
product in any way. BabySense LLC is not liable for any
incidental or consequential damage with regard to this
product. Warranty also excludes any liability other than
above. No other warranties are given. If you have a
claim under this warranty, do not return to the store.
Please contact BabySense customer service at:
customerservice@babysensellc.com
Distributed by:
BabySense LLC
3910 Adler Place
Suite 115
Bethlehem, PA 18017
For additional information, please visit our website or
call the toll free number:
Website: www.babysensellc.com
Toll free number: 1-877-780-3033
Made by Hisense Ltd.
ISO 9001:2008 and ISO 13485:2003 certified
23, Becker St. Rishon le Zion 7535929, Israel
www.hisense.co.il
5
5
S
Infant Movement Monitor
User Guide
English
S i n c e 1 9 9 1

Advertisement

loading