Thermostat Application Guide
Description
Gas or Oil Heat
Electric Furnace
Heat Pump (No Aux. or Emergency Heat)
Heat Pump (With Aux. or Emergency Heat)
Multi-Stage Systems
Heat Only Systems
Heat Only Systems - Floor or Wall Furnace
Cool Only Systems
Millivolt Conventional Systems
Two Transformer Systems
Table of Contents

Specifications

Installation Tips
Thermostat Quick Reference
Wiring
Technician Setup
Specifications
The display range of temperature ... 41˚F to 95˚F (5˚C to 35˚C)
The control range of temperature.... 44˚F to 90˚F (7˚C to 32˚C)
Swing (cycle rate or differential) ...... Heating is adjustable from 0.2˚ to 2.0˚
Power source ...........................................18 to 30 VAC, NEC Class II, 50/60 Hz
Operating ambient ............................... 32˚F to +105˚F (0˚C to +41˚C)
Operating humidity .............................. 90% non-condensing maximum
Dimensions of thermostat ................. 4.7"W x 4.4"H x 0.8"D
U.S. Registered Trademark. Patents pending
Copyright
2018 All Rights Reserved.
Installation Tips

Mount Thermostat

Align the 4 tabs on the subbase with
corresponding slots on the back of the
thermostat, then push gently until the
thermostat snaps in place.

Battery Installation

Battery installation is recommended even if thermostat is hardwired
(C terminal connected). When thermostat is hardwired and batteries
are installed, the thermostat will activate a compressor delay of 5
minutes when the thermostat detects a power outage from the
hardwired power supply.
Important:
High quality alkaline batteries are recommended.
Rechargeable batteries or low quality batteries
do not guarantee a 1-year lifespan.
Insert 2 AA
Alkaline batteries
(included). High
quality alkaline
batteries are
recommended.
TP-N-721
Power Type
Battery Power
Hardwire (Common Wire)
Yes
Hardwire (Common Wire) with
Yes
Battery Backup
Yes
Yes
Yes
A trained, experienced
Yes
technician must install this
Yes
product.
Yes
Yes
Carefully read these
No
instructions. You could damage
this product or cause a
Page
hazardous condition if you fail
1
to follow these instructions.
2-3
4
Una version en español de este
5-6
manual se puede descargar en
7-8
la pagina web de la compañia.
Cooling is adjustable from 0.2˚ to 2.0˚
for hardwire
Battery power from 2 AA Alkaline
batteries
ON AUTO
Wall Locations
The thermostat should be installed approximately 4 to 5 feet above the
floor. Select an area with average temperature and good air circulation.
Installation Tip
Pick an installation location that is easy for
the user to access. The temperature of the
location should be representative of the
building.

Subbase Installation

Horizontal Mount
Vertical Mount
For vertical mount put one screw on the
top and one screw on the bottom.
For horizontal mount put one screw on
the left and one screw on the right.
Rev. 1821
Getting to know your thermostat
FAN
ON AUTO
FAN
OFF
HEAT
COOL
EmH
LCD
Glow in the dark light button
Fan switch
System switch
Easy change battery door
Temperature setpoint buttons
Removing The Private
Label Badge
Use the bevel on lower ridge
Simple
operating
instructions
are found
on the back
Magnet in door
of the
battery
About The Badge
door.
All of our thermostats use the same universal magnetic badge. Visit the
company website to learn more about our free private label program.
thermostat in locations:
• Close to hot or cold air ducts
• That are in direct sunlight
• With an outside wall behind
the thermostat
• In areas that do not require
conditioning
• Where there are dead spots
or drafts
(in corners or behind doors)
• Where there might be
concealed chimneys or
pipes
Installation Tip:
Electrical Hazard
Failure to disconnect the power before
beginning to install this product can
cause electrical shock or equipment
damage.
Mercury Notice
All of our products are mercury free.
However, if the product you are
replacing contains mercury, dispose of
it properly. Your local waste
management authority can give you
instructions on recycling and proper
disposal.
Thermostat Quick Reference
Room Temperature
88
Stage 1 & 2
OFF
HEAT
COOL
EmH
Low Battery Indicator:
Replace batteries when
indicator is shown.
Indicates the current
room temperature.
Stage 1 and 2 indicate the
stages of HEAT that are active.
Important
The low battery indicator is displayed when the
AA battery power is low. If the user fails to
replace the battery within 21 days, the screen
will only show the low battery indicator but
maintain all functionality. If the user fails to
replace the batteries after an additional 21 days
(days 22-42 since first "low battery" display) the
setpoints will change to 55˚F (Heating) and 85˚F
(Cooling). If the user adjusts the setpoint away
from either of these, it will hold for 4 hours
then return to either 55˚F or 85˚F. After day 63
the batteries must be replaced immediately to
avoid freezing or overheating because the
thermostat will shut the unit off until the
batteries are changed.
Gently slide a screwdriver into the
bottom edge of the badge. Gently turn
the screwdriver counter clockwise. The
badge is held on by a magnet in the well
of the battery door. The badge should pry
off easily. DO NOT USE FORCE.
Installation Tips
Do not install
Displays the
Set At
selected setpoint
88
temperature.
o
C
System Operation
COOL ON
Indicators:
HEAT ON
The COOL, HEAT,
EmH ON
EmH or
icon will
F
display when
the COOL, HEAT, or
LOW
(fan) is on.
NOTE: The
=
compressor delay
feature is active if
these icons are
flashing. The
compressor will not
turn on until the 5
minute delay has
elapsed.

Advertisement

loading

Summary of Contents for Vive Comfort TP-N-721

  • Page 1: Subbase Installation

    Installation Manual Installation Tips TP-N-721 Wall Locations The thermostat should be installed approximately 4 to 5 feet above the floor. Select an area with average temperature and good air circulation. Vive Comfort Do not install P.O. Box 3377 thermostat in locations: Springfield, MO 65808-3377 •...
  • Page 2: Terminal Designations

    Wiring Wiring Diagrams Power supply Caution: Warning: Electrical Hazard Use either O or B terminals for changeover valve. Failure to disconnect the power All components of the Optional 24 VAC common connection when thermostat is used in battery power mode. before beginning to install this control system and the Factory-supplied jumper...