Error Code Table; Cassette Mechanism Self-Diagnostic Mode - Panasonic SA-PM31P Service Manual

Table of Contents

Advertisement

SA-PM31P / SA-PM31PC

11.4. Error Code Table

11.4.1. Error code for Power Supply
Error Code
F61
POWER AMP output
abnormal
11.4.2. Error codes for CD Mechanism
Error Code
F15
CD REST SW abnormal
F26
CD servo LSI command
signal abnormal
F28
DISC LOAD abnormal
F29
DISC unload abnormal
F27
Slide operation abnormal
F17
Down SW abnormal
F22
Loading Mode / Mecha
abnormal
11.4.3. Error codes for Cassette Mechanism
Error Code
H01
MODE SW abnormal
H02
REC INH SW abnormal
H03
HALF SW abnormal
F01
Reel pulse abnormal
F02
TPS abnormal

11.5. Cassette Mechanism Self-Diagnostic Mode

1. A Cr02-positioned blank cassette tape with an erase prevention niche on either Side A or B.
2. A normal-positioned music tape with erase prevention niches on both Sides A and B. Both tapes are halfway forwarded in
advance.
3. The remote controller that comes with this unit.
No.
1
C-mecha Abnormal Detection shall be
executed for DECK 1 only.
2
[
] key is pressed, after loading in a
NORMAL type cassette with the recording tab
on the left side removed.
3
[
] key is pressed, after loading a NORMAL,
CrO2, METAL type cassette with the recording
tab on the right side removed.
Abnormal Items
During normal operation, if either DCDET1 or DCDET2 becomes L, normal POWER OFF
process shall not be executed, PCNT shall be switched to L immediately. GOODBYE shall not
display and the error display F61 is displayed instead. 2 seconds after the F61 display, ECONO
shall be set to ´L´ and LCD display shall be turned off. The error content shall be memorised
when the abnormality occurs and can be display in the C-mecha self-diagnostic mode described
later.
Abnormal Items
CD traverse position intial setting operation failsafe counter (1000 ms) waiting for REST SW to
turn on. Error No. shall be clear by force or during coldstart.
CD function DTMS command, after system setting, If SENSE = 'L' cannot be detected.
Memory shall contain F26 code. After Power on, CD function shall continue, error shall occur
"NO DISC".
Error No. shall be clear by force or coldstart.
While going to play position, if failsafe counter is finished and switch o change or switch
target condition was not achieve, this error shall be memorized. Next time mechanism
operates, it shall do coldstart.
Error No. shall be clear by force or coldstart.
While going to play position, if failsafe counter is finished and switch no change or switch
target condition was not achieve, this error shall be memorized. Next time mechanism
operates, it shall do coldstart.
Error No. shall be clear by force or coldstart.
During vertical operation, if failsafe timer is finished and switch no change or switch target
condition was not achieve, this error shall be memorized. Next time mechanism operates, it
shall do coldstart.Error No. shall be clear by force or coldstart.
During vertical operation going to the bottom position, if failsafe timer is finished and switch
no change or switch target condition was not achieve, this error shall be memorized. The
Next time mechanism operates, it shall do mechanism initialization.Error No. shall be clear by
force or coldstart.
During mecha initialization, Loading mode mechanism abnormal, normal operation cannot be
achieve. The next time mechanism operates, it shall do mechanism initialization.Error No.
shall be clear by force or coldstart.
Abnormal Items
Normal operation during mecha transition, MODE SW abnormal is memorised. The content
of abnormality can be confirmed in the abnormal detection mode explained in the later
section.
The content of abnormality can be confirmed in the abnormal detection mode explained in
the later section.
Operation Procedures
Possible Cause
Possible Cause
Possible Cause
Micon operation & processing
Check that all DECK mechanism leaf SW are in OFF state.
FF shall be executed for 2 sec, afterwhich STOP.
Check the following.
{ F.REC INH SW } is OFF
{ R.REC INH SW } is ON
{ HALF SW } is ON
Reel pulse toggles between H & L.
REW shall be executed for 2 sec, afterwhich STOP.
Check the following.
{ F.REC INH SW } is ON
{ R.REC INH SW } is OFF
{ HALF SW } is ON
Reel pulse toggles between H & L.
52

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sa-pm31pc

Table of Contents