Disassembly Of Main Control P.c.b., Function P.c.b. And; Power-In P.c.b; Disassembly Of Panel P.c.b - Panasonic SA-PM31P Service Manual

Table of Contents

Advertisement

SA-PM31P / SA-PM31PC
Step 3 : Release 2 catches and remove the front panel as
arrows shown.
Step 4 : Release the catch at the bottom cabinet as shown.
9.6.
Disassembly of Main Control
P.C.B., Function P.C.B. and

Power-In P.C.B.

· Follow the (Step 1) - (Step 6) of Item 9.2.
· Follow the (Step 1) - (Step 3) of Item 9.3.
· Follow the (Step 1) - (Step 4) of Item 9.5.
· Disassembly of Function P.C.B. and Power-In P.C.B.
Step 1 : Remove 5 screws.
Step 2 : Release 2 clutches and remove both Function P.C.B.
and Power-In P.C.B.
· Disassembly of Main Control P.C.B.
Step 3 : Remove 2 screws to remove the shield plate.
Step 4 : Remove 2 screws and flip the Main Control P.C.B. as
arrow shown.
Step 5 : Detach the connector CN603A.
9.7.

Disassembly of Panel P.C.B.

· Follow the (Step 1) - (Step 6) of Item 9.2.
· Follow the (Step 1) - (Step 3) of Item 9.3.
· Follow the (Step 1) - (Step 4) of Item 9.5.
· Follow the (Step 1) - (Step 5) of Item 9.6.
14

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sa-pm31pc