Semtech TS8000 User Manual

Ts8x series device gui loaded device
Hide thumbs Also See for TS8000:

Advertisement

TS8X Series Device GUI Loaded Device
User Manual
POWER PRODUCTS
TS8X Series Device GUI
Loaded Device
User Manual
Rev 1.2
© 2015 Semtech Corp.
www.semtech.com
1 of 12

Advertisement

Table of Contents
loading

Summary of Contents for Semtech TS8000

  • Page 1 TS8X Series Device GUI Loaded Device User Manual POWER PRODUCTS TS8X Series Device GUI Loaded Device User Manual Rev 1.2 © 2015 Semtech Corp. www.semtech.com 1 of 12...
  • Page 2: Table Of Contents

    Toggle Tx between BOOTLOADER and TRANSMITTER Mode....5 Adjust Parameters and run APIs..............5 BOOTLOADER mode...................6 Register......................6 Api........................7 Configuration....................8 Calibration......................8 Firmware......................9 2.5.1 Merge.......................9 2.5.2 Program....................10 2.5.3 Firmware Version...................10 TRANSMITTER mode..................10 Register......................10 Api........................11 Rev 1.2 © 2015 Semtech Corp. www.semtech.com 2 of 12...
  • Page 3: Table Of Figures

    Figure 5: Configuration of BOOTLOADER Mode............8 Figure 6: Calibration of BOOTLOADER Mode............8 Figure 7: Firmware of BOOTLOADER Mode..............9 Figure 8: Register of TRANSMITTER Mode.............10 Figure 9: API of TRANSMITTER Mode..............11 Rev 1.2 © 2015 Semtech Corp. www.semtech.com 3 of 12...
  • Page 4: Quick Start

    Follow below procedures to connect the Tx board to GUI. 1. Connect Tx board micro USB to PC. 2. Run GUI “TS8XGUI” Mode = BOOTLOADER, Com = USB-HID, Check Status Every 100ms Status is “Disconnected” now Rev 1.2 © 2015 Semtech Corp. www.semtech.com 4 of 12...
  • Page 5: Adjust Parameters

    1.6 Adjust Parameters and run APIs In BOOTLOADER Mode, there are 5 tabs including Register, Configuration, Calibration, Firmware, for customer to adjust parameters to Tx or read information from Tx. Rev 1.2 © 2015 Semtech Corp. www.semtech.com 5 of 12...
  • Page 6: Bootloader Mode

    Check to read all resiger automatically. To change setting of a read-write register, double click its Value or Bit Field to open Bit Value Edit window. Rev 1.2 © 2015 Semtech Corp. www.semtech.com 6 of 12...
  • Page 7: Api

    Click to toggle bit between 1 and 0. Then click button and button. The Register in TRANSMITTER Mode is similar with BOOTLOADER Mode. 2.2 Api Figure 4: API of BOOTLOADER Mode Click “Run” to run the desire application Rev 1.2 © 2015 Semtech Corp. www.semtech.com 7 of 12...
  • Page 8: Configuration

    TS8X Series Device GUI Loaded Device User Manual POWER PRODUCTS 2.3 Configuration Figure 5: Configuration of BOOTLOADER Mode 2.4 Calibration Figure 6: Calibration of BOOTLOADER Mode Rev 1.2 © 2015 Semtech Corp. www.semtech.com 8 of 12...
  • Page 9: Firmware

    2. Click to select a Configuration file to merege i.e. 3. Click to select a Calibration file to merege i.e. 4. Click Merge button , input a file name. i.e. The merge file has been gerenated Rev 1.2 © 2015 Semtech Corp. www.semtech.com 9 of 12...
  • Page 10: Program

    User Manual POWER PRODUCTS 2.5.2 Program To program Image bin file to a TS8000 Tx board, follow below steps: 1. Click to select an Image bin file to program i.e. 2. Check which portion you’d like to program to Tx 3.
  • Page 11: Api

    TS8X Series Device GUI Loaded Device User Manual POWER PRODUCTS 3.2 Api Figure 9: API of TRANSMITTER Mode Click “Run” to run the desire application Rev 1.2 © 2015 Semtech Corp. www.semtech.com 11 of 12...
  • Page 12 Publication thereof does not convey nor imply any license under patent or other industrial or intellectual property rights. Semtech assumes no responsibility or liability whatsoever for any failure or unexpected operation resulting from misuse,...

Table of Contents