LEAKS — Check any connections that show evidence of oil
or leaks. When unit is properly installed, centered, and lev-
eled (see Owners' Guide), check gaskets and wing panels
for possible air leakage.
CONTROLS — Check unit to ensure all controls are func-
tioning correctly and unit operation is normal.
Table 2 — Physical and Electrical Data — 1993-1995 Model Offerings
SERVICE/
CASING
DISCRETE
(See Table 6)
NO.
73TCA005101B
S-1
73TCA005111B
S-1
73TCA005121B
S-1
73TCA005131B
S-1
73TCA005141B
S-1
73TCA005151B
S-1
73TCA005171B
S-1
73TCA005101D
S-1
73TCA005101L
S-1
73TCA005111L
S-1
73TCA005121L
S-1
73TCA006101D
S-1
73TCA006111D
S-1
73TCA006121D
S-1
73TCA008101D
S-2
73TCA008101P
S-2
73TCA010101D
S-2
SERVICE/
PF
DISCRETE
(%)
NO.
73TCA005101B
96
73TCA005111B
96
73TCA005121B
96
73TCA005131B
96
73TCA005141B
96
73TCA005151B
96
73TCA005171B
96
73TCA005101D
91
73TCA005101L
96
73TCA005111L
96
73TCA005121L
96
73TCA006101D
92
73TCA006111D
91
73TCA006121D
91
73TCA008101D
99
73TCA008101P
99
73TCA010101D
98
LEGEND
AHAM — Association of Home Appliance Manufacturers
ANSI
— American National Standards Institute
DOE
— Department of Energy
EER
— Energy Efficiency Ratio
FLA
— Full Load Amps
PF
— Power Factor
V-PH-Hz
VOLTAGE
RANGE
115-1-60
115
104-127
115
104-127
115
104-127
115
104-127
115
104-127
115
104-127
115
104-127
115
104-127
115
104-127
115
104-127
115
104-127
115
104-127
115
104-127
115
104-127
115
104-127
115
104-127
115
104-127
FAN MTR
CAPACITOR
CARRIER
(See Table 5)
P/N
RC-1/FC-1
HC01CE118
RC-1/FC-1
HC01CE118
RC-2/FC-1
HC01CE118
RC-2/FC-1
HC01CE117
RC-1/FC-1
HC01CE118
RC-2/FC-1
HC01CE118
RC-2/FC-1
HC01CE118
RC-2/FC-1
HC01CE117
RC-1/FC-1
HC01CE118
RC-2/FC-1
HC01CE118
RC-2/FC-1
HC01CE118
RC-2/FC-1
HC01CE117
RC-2/FC-1
HC01CE118
RC-2/FC-1
HC01CE118
RC-3
HC43CE115
RC-4
HC33CE116
RC-4
HC33CE116
Vibrations can cause unwanted noise. Check to be sure no
piping is vibrating against any side of unit.
System Cleaning/Flushing —
and flushing, use the Carrier Totalclaim recovery system, or
a comparable refrigerant recycling system.
COOLING
R-22
CAPACITY*
CHARGE
(Btuh)
(OZ. ± .05)
5100
10.00
5100
13.00
5000
13.70
5000
13.70
5000
10.20
5000
10.20
5000
9.20
5400
11.25
5100
10.00
5000
10.20
5000
9.20
6000
12.50
6000
13.50
6000
13.50
8000
21.50
8600
22.25
9900
24.00
FAN MTR
COMPRESSOR
FLA
(See Table 7)
0.74
D-1
0.74
D-2
0.74
M-1
0.70
M-1
0.74
D-3
0.74
D-3
0.74
D-3
0.74
M-1
0.74
D-1
0.74
D-3
0.74
D-3
0.74
M-2
0.70
D-4
0.70
D-4
1.25
T-1
1.60
T-1
1.60
T-2
t — Entering wet-bulb temperature minus leaving wet-bulb tem-
perature based on 67 F room wet-bulb temperature and 95 F
dry-bulb outside-air temperature. If conditions vary, wet-bulb t
will vary.
*Based on AHAM Standard RAC-1 and ANSI Z234.1.
3
For proper cleaning
WET BULB
AMPS
WATTS
t F
7.5
5.7
630
7.5
5.7
630
7.5
5.4
593
7.5
5.4
593
7.5
5.9
630
7.5
5.9
630
7.5
5.9
625
12.0
5.4
593
7.5
5.7
630
7.5
5.9
630
7.5
5.9
625
11.6
6.5
691
13.0
6.7
697
13.0
6.7
697
12.1
7.5
870
12.2
7.5
862
15.5
9.4
1092
CAPILLARY
THERMISTOR
DATA
(See Table 4)
(See Table 3)
Z-1
CD-1
Z-1
CD-2
Z-1
CD-3
Z-1
CD-3
Z-1
CD-4
Z-1
CD-4
Z-1
CD-4
Z-1
CD-5
Z-1
CD-1
Z-1
CD-4
Z-1
CD-4
Z-1
CD-6
Z-1
CD-7
Z-1
CD-7
Z-1
CD-8
Z-1
CD-9
Z-1
CD-10
EER
(DOE)
8.1
8.1
8.0
8.0
8.0
8.0
8.0
9.1
8.1
8.0
8.0
8.6
8.6
8.6
9.2
10.0
9.0