Genie GTH-5519 Service And Repair Manual page 62

Deutz tier 4i
Hide thumbs Also See for GTH-5519:
Table of Contents

Advertisement

Section 4 • Fault Codes
FAULT CODES
SPN
FMI
Short Text Detail
523914
3
Glow plug control; short circuit to battery
523914
4
Glow plug control; short circuit to ground
639
14
CAN-Bus 0 "BusOff-Status"
1231
14
CAN-Bus 1 "BusOff-Status"
1235
14
CAN-Bus 2 "BusOff-Status"
102
2
Charged air pressure above warning threshold
102
2
Charged air pressure above shut off threshold
110
3
Sensor error coolant temperature; signal range check high
110
4
Sensor error coolant temperature; signal range check low
110
0
High coolant temperature; warning threshold exceeded
110
0
High coolant temperature; shut off threshold exceeded
111
1
Coolant level too low
523929
0
Fuel Balance Control integrator injector 1 (in firing order); maximum value exceeded
523930
0
Fuel Balance Control integrator injector 2 (in firing order); maximum value exceeded
523931
0
Fuel Balance Control integrator injector 3 (in firing order); maximum value exceeded
523932
0
Fuel Balance Control integrator injector 4 (in firing order); maximum value exceeded
523933
0
Fuel Balance Control integrator injector 5 (in firing order); maximum value exceeded
523934
0
Fuel Balance Control integrator injector 6 (in firing order); maximum value exceeded
523929
1
Fuel Balance Control integrator injector 1 (in firing order); minimum value exceeded
523930
1
Fuel Balance Control integrator injector 2 (in firing order); minimum value exceeded
523931
1
Fuel Balance Control integrator injector 3 (in firing order); minimum value exceeded
523932
1
Fuel Balance Control integrator injector 4 (in firing order); minimum value exceeded
523933
1
Fuel Balance Control integrator injector 5 (in firing order); minimum value exceeded
523934
1
Fuel Balance Control integrator injector 6 (in firing order); minimum value exceeded
1109
2
Engine shut off demand ignored
523698
11
Shut off request from supervisory monitoring function
523717
12
Timeout Error of CAN-Transmit-Frame AmbCon; Weather environments
523603
9
Timeout Error of CAN-Receive-Frame AMB; Ambient Temperature Sensor
3224
2
DLC Error of CAN-Receive-Frame AT1IG1 NOX Sensor (SCR-system upstream cat; DPF-system downstream cat); length of
frame incorrect
3224
9
Timeout Error of CAN-Receive-Frame AT1IG1; NOX sensor upstream
3224
2
DLC Error of CAN-Receive-Frame AT1IG1Vol NOX Sensor (SCR-system upstream cat; DPF-system downstream cat); length
of frame incorrect
3224
9
Timeout Error of CAN-Receive-Frame AT1IG1Vol; NOX sensor (SCR-system upstream cat; DPF-system downstream cat)
4-4
GTH-5519
September 2016
Part No. 1272852

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents