Running Average Measurement Mode - Kanomax 6710 Instruction Manual

Capture hood
Hide thumbs Also See for 6710:
Table of Contents

Advertisement

1)"Single" measurements are individual flow measurements. When you press "START", the
instrument will begin measuring and the air flow value will be displayed as "- - - -".
2)The test will stop automatically when the air flow is stable and a flow value with the
corresponding wind direction will be displayed. Air flow will be stable within 8 seconds.
The greater the air flow the shorter the time needed to stabilize.
3)After the measurement stops, press "SAVE" to record the testing value, if you do the
"Cycle" No. will increase by 1.
Note:The value will be recorded only when testing is completed in the "Single" mode. If

4.7.3 Running Average Measurement Mode

1)When "Run Avg" mode is selected, the instrument will constantly measure and display a
running average. Press "START" to begin the measurement.
2)During the test if the air flow is not stable, the flow reading will display "- - - -", then once the
reading has stabilized a flow reading will be obtained and displayed every 1 second, and
the wind direction will be displayed in real time.
Note: The displayed air flow reading is a running average that is calculated based on the "Avg
3)When auto-save is enabled, the testing flow values will be recorded at user-defined
intervals under the setting "Save Time", and the "Cycle" No. will increase by 1. If auto-save
is not enabled the readings will not be saved during the test.
4)The instrument will run continuously in "Run Avg" mode until you press "STOP". After you
press stop, the last reading and the related wind direction will be displayed. Press "SAVE"
to record the testing value, if you do the "Cycle" No. will increase by 1.
2012 / 06 / 01 13 : 10 : 10
Test ID
- - - -
25.4
1.800.561.8187
testing is interrupted before a stable airflow reading is displayed no data will be saved.
Time" settings entered by the user. The greater the "Avg Time" the more stable the
tested air flow.
Test Mode :
Cycle
: 050
: 13
Single
SAVE
m³/h
START
53.4
MENU
%RH
www.
2012 / 06 / 01 13 : 10 : 10
Test ID
: 13
2890
25.4
information@itm.com
.com
11
Test Mode :
Cycle
: 050
Single
SAVE
m³/h
START
53.4
MENU
%RH