Download Print this page

Performance Summary; Quick Start Procedure - Linear LTM4650 Demo Manual

High efficiency, single 50a or dual 25a step-down power µmodule regulator

Advertisement

DEMO MANUAL DC2378A-A

performance summary

PARAMETER
Input Voltage Range
Output Voltage V
OUT1
Output Voltage V
OUT2
Per-Channel Maximum Continuous Output
Current
Default Operating Frequency
Resistor Programmable Frequency Range
External Clock Sync. Frequency Range
Efficiency of Channel 1
Efficiency of Channel 2
Load Transient of Channel1
Load Transient of Channel2

Quick start proceDure

Demonstration circuit DC2378A-A is easy to set up to
evaluate the performance of the LTM4650EY. Please refer
to Figure 2 for proper measurement setup and follow the
procedure below:
1. Place jumpers in the following positions for a typical
application:
JP1
JP2
MODE
RUN1
CCM
ON
2. With power off, connect the input power supply, load
and meters as shown in Figure 2. Preset the load to 0A
and V
supply to 12V.
IN
3. Turn on the power supply at the input. The output
voltage in channel 1 should be 1.5V ±1.5% (1.4775V
~ 1.5225V) and the output voltage in channel 2 should
be 1V ±1.5% (0.985V ~ 1.015V).
4. Once the proper output voltage is established, adjust the
load within the operating range and observe the output
voltage regulation, output voltage ripple, efficiency and
other parameters. Output ripple should be measured
at J1 and J2 with BNC cables. 50Ω termination should
be set on the oscilloscope or BNC cables.
2
Specifications are at T
CONDITIONS
V
= 4.5V ~ 15V, I
IN
OUT1
V
= 4.5V ~ 15V, I
IN
OUT2
Derating Is Necessary for Certain V
Thermal Conditions, See Data Sheet for Detail.
V
= 12V, V
= 1.5V, I
IN
OUT1
V
= 12V, V
= 1V, I
IN
OUT2
V
= 12V, V
= 1.5V, I
IN
OUT1
V
= 12V, V
= 1V, I
IN
OUT2
JP3
JP4
JP5
RUN2
TRACK1
TRACK2
SEL.
SEL.
ON
SOFT-
SOFT-
START
START
= 25°C
A
= 0A ~ 25A, JP1: CCM
= 0A ~ 25A, JP1: CCM
, V
and
IN
OUT
= 25A, f
= 500kHz
OUT1
SW
= 25A, f
= 500kHz
OUT2
SW
= 12.5A ~ 18.75A
STEP
= 12.5A ~ 18.75A
STEP
5. (Optional) For optional load transient test, apply an
adjustable pulse signal between IOSTEP CLK and GND
test point. Pulse amplitude (3V ~ 3.5V) sets the load
step current amplitude. The output transient current
can be monitored at the BNC connector J3 (10mV/A).
The pulse signal should have very small duty cycle (<
1%) to limit the thermal stress on the transient load
circuit. Switch the jumper resistors R34 or R35 (on the
backside of boards) to apply load transient on channel
1 or channel 2 correspondingly.
6. (Optional) LTM4650 can be synchronized to an external
clock signal. Place the JP1 jumper on EXT_CLK and
apply a clock signal (0V ~ 5V, square wave) on the
CLKIN test point.
7. (Optional) The outputs of LTM4650 can track another
supply. The jumpers JP4 and JP5 allow choosing soft-
start or output tracking. If tracking external voltage is
selected, the corresponding test points, TRACK1 and
TRACK2, need to be connected to a valid voltage signal.
8. (Optional) LTM4650 can be configured for a 2-phase
single output at up to 50A on DC2378A-A. Install 0Ω
resistors on R14, R17, R28, R39, R43, R44, R45 and
remove R7, R19. Output voltage is set by R25 based
on equation V
OUT
MIN
TYP
MAX
4.5
15
1.5 ±1.5%
1 ±1.5%
25
(Per-Channel)
500
250
780
400
780
88.8
See Figure 4
86.5
See Figure 5
See Figure 6
See Figure 7
= 0.6V(1 + 60.4k/R25).
UNITS
V
V
V
A
kHz
kHz
kHz
%
%
dc2378aaf

Advertisement

loading