Parameter
Table 2. Environmental parameters
Parameter
Operating temperature
Operating humidity
Storage temperature
Storage humidity
Maximum thermal output
Maximum operational altitude
Maximum non-operational altitude
Shock
Table 3. AC power requirements
Parameter
Power supply
Maximum current draw per system
Maximum power consumption*
Specifications
Back: 5 inches (12.7 cm)
Specifications
0°C to 45°C (23°F to 113°F) continuously
-5°C to 45°C (23°F to 113°F) short term
Short term is </= 1% of operational hours
per year.
NOTE:
Reduce maximum
temperature by 1°C/125 meters
(1°F/228 feet) above 950 meters
(3,117 feet).
5% to 90% (RH), non-condensing
–40° to 70°C (–40° to 158°F )
5% to 90%, non-condensing
500 W = 1706 BTU/Hr
10,000 feet (3,048 meters)
35,000 feet (10,668 meters)
Dell EMC Spec SV0115
Specifications
100–240 VAC 50/60 Hz
5A/4.17A at 100/120V AC 2.5A/2.1A at
200/240V AC
5-fan 16-core CPU: 300W
4-fan 8-core CPU: 230W
Specifications
21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vep4600

Table of Contents