Drain Pump Installation - KitchenAid KUIC15NHZS Use & Care Manual

Hide thumbs Also See for KUIC15NHZS:
Table of Contents

Advertisement

Rear View
A. Copper tubing
B. Water supply tube clamp
6. Remove and discard the short, black plastic tube from the
end of the water line inlet.
7. Thread the nut onto the end of the tubing. Tighten the nut
by hand. Then tighten it with a wrench 2 more turns. Do
not overtighten.
NOTE: To avoid rattling, be sure the copper tubing does not
touch the cabinet's side wall or other parts inside the cabinet.
A
B
C
A. Line to ice maker
B. Nut (purchased)
8. Install the water supply tube clamp around the water supply
line to reduce strain on the coupling.
9. Turn shut-off valve on.
10. Check for leaks. Tighten any connections (including
connections at the valve) or nuts that leak.

Drain Pump Installation

(on some models)
NOTES:
Connect drain pump to your drain in accordance with all state
and local codes and ordinances.
It may be desirable to insulate drain tube thoroughly up
to drain inlet to minimize condensation on the drain tube.
Insulated tube kit Part Number W10365792 is available for
purchase.
Drain pump is designed to pump water to a maximum height
of 10 ft (3 m). Use only Whirlpool approved drain pump kit
Part Number 1901A.
Do not connect the outlet end of the drain tube to a closed
pipe system to keep drain water from backing up into the
ice maker.
Kit Contains:
Drain pump kit Part Number 1901A
⁵⁄₈" I.D. (inside diameter) x 5¹⁄₈" drain tube (ice maker bin to
drain pump reservoir inlet)
¹⁄₂" I.D. x 10 ft (3 m) drain tube hose (drain pump discharge
to household drain)
6 6 6 6 6 6
A
B
C
C. Inlet water tube clamp and
supply line connector
D
C. Ferrule (purchased)
D. Supplied line from ice maker
⁵⁄₁₆" I.D. x 32" (81 cm) vent tube (drain pump reservoir vent
to ice maker cabinet back)
Cable clamps (secures vent tube to back of ice maker) (3)
#8-32 x ³⁄₈" pump mounting screws (secures drain pump to
baseplate and clamps to back of ice maker) (5)
⁵⁄₈" small adjustable hose clamp (secures vent to drain pump)
⁷⁄₈" large adjustable hose clamp (secures drain tube to ice
maker bin and drain pump reservoir inlet) (3)
Rear panel (2)
Instruction sheet
If Ice Maker Is Currently Installed
NOTE: If ice maker is not installed, please proceed to "Drain
Pump Installation" section.
1. Push the selector switch to the Off position.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
2. Unplug ice maker or disconnect power.
3. Turn off water supply. Wait 5 to 10 minutes for the ice to fall
into the storage bin. Remove all ice from bin.
4. Unscrew the drain cap from the bottom of the water
pan located inside the storage bin. Allow water to drain
completely. Replace drain cap. See "Drain Cap" illustration.
Drain Cap
A
A. Drain cap
5. If ice maker is built into cabinets, pull ice maker out of the
opening.
6. Disconnect water supply line. See "Water Supply Line"
illustration.

Hide quick links:

Advertisement

Table of Contents
loading