Download Print this page

Specifications - Extech Instruments LT510 User Manual

Light meter

Advertisement

Specifications

Find Quality Products Online at:
Display
Light sensor
Measurement Units
Input Overload Display
Tripod mount
Power
Power Consumption
Automatic power off
Operating temperature
Operating humidity
Storage temperature
Storage humidity
Dimensions/weight
Electrical Specifications (23±5°C)
Lux
(autorange)
Unit
Range
Lux
0 to 2,200
1,800 to 20,000
Ft-cd (autorange)
Unit
Range
Ft-cd
0 to 204.0
170 to 1,860
Copyright © 2017 FLIR Systems, Inc.
All rights reserved including the right of reproduction in whole or in part in any form
GlobalTestSupply
www.
Backlit LCD 35 x 30mm (1.38 x 1.18")
Photo sensor with cosine correction filter
LUX and Ft-cd (Foot – Candle)
"----"
On back of meter
3 x 1.5V AAA batteries
Approx. 5mA DC
After approx. 10 minutes of inactivity
0 to 50
o
C (32 to 122
o
F)
80% RH max
-10 to 60
o
C (14 to 140
o
F)
10 to 75% RH
141 x 57 x 25mm (5.5 x 2.3 x 1.1") /136g (4.8oz)
Resolution
Accuracy
1
±5%rdg ±8dgt
10
Resolution
Accuracy
0.1
±5%rdg ±8dgt
1
ISO-9001 Certified
6
.com
LT510-en-GB_V1.0 5/17