This User Manual does not address the end-user. It is intended as a source of information for the manufacturer of the equipment or system only, and it will tell you how to install, use and maintain your LINAK electronics. It is the responsibility of the manufacturer of the end-user product to provide a User Manual where relevant safety information from this manual is passed on to the end-user.
Valid for: This User Manual is valid for the following products: (See the first 3 - 5 characters on the label) Columns: 1 single DL5/DL6 or 2 in parallel Control boxes: CBD6S 200 W, CBD6S 300 W Controls: DP1U/DPF1M/DPG1M/DPG1B (if memory function is required) DP1C/DPT/DPF1C/DPG1C (if memory function and display is required) or DPA/DPB/DPH/DP1K/DP1V/DPF1K/DPG1K (if only up/down is required) or DPF1D (if display is required).
Important information Important information on LINAK products can be found under the following ® headings: Warning! Failure to comply with these instructions may result in accidents involving serious personal injury. Failing to follow these instructions can result in the product being damaged or being destroyed.
• System connection. The individual parts must be connected before connecting the control box to the mains. See the User Manual for LINAK actuators, if necessary. During operation • If the control box makes unusual noise or smells, switch off the mains voltage immediately.
Only for EU markets This appliance can be used by children aged from aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Repairs In order to avoid the risk of malfunction, all DESKLINE repairs must only be carried out by authorised LINAK workshops or ® repairers, as special tools must be used and special gaskets must be fitted. Lifting units under warranty must also be returned to authorised LINAK workshops.
Misc. on the DESKLINE DL5/DL6 system ® This system is a DESKLINE system developed for desks and for indoor use in offices. Do not use it in industrial kitchens or in other enviroments that have to be cleaned with aggressive detergents. Do not bolt the legs to the floor so that free movement is prevented.
ETL-marking Due to space limitations, the complete ETL-marking demands are not represented on the marking plates. The full ETL Recognized Component markings are shown here. C/N 120690 Conforms to UL962 Cert. to CSA Std. C22.2 No. 68-09 ETL Recognized Component mark for Canada and United States C/N 9901916 Conforms to UL962...
Description of the DESKLINE DL5/DL6 system ® Each DESKLINE DL5/DL6 lifting units is equipped with a motor and parallel/memory drive is ensured by means of software in ® the CBD6S (SMPS) that also takes account of oblique load on the desk. Soft start and stop are also part of this software, which ensures a soft start and stop when adjusting the desk.
Mounting guidelines for the DESKLINE DL5/DL6 system The lifting units are normally mounted with the motor housings upwards and pointing towards each other. The steel motor housing is supplied with 6 pcs. of M6 threaded holes meant for mounting on the desk frame. The motor housing is supplied with 6 pcs.
Mounting of the foot part The DL5/DL6 is supplied with 4 threaded holes M6 for mounting of the foot. We advise you to fasten the foot by means of 4 screws M6 of a good quality (min. 8.8) and of a suitable length; it must go min. 10 mm into the DL5/DL6 column and not further than 16 mm.
Mounting guidelines for the crossbar If the crossbar connection is made with a design where the bracket is hidden inside the crossbar profile, you have to make sure that you do not pull out the bracket in the column when tightening the screws for the assembly. The maximum torque for tightening the 2 x M8 screws in the bracket should not exceed 15 Nm.
Desks with crossbar Min. 1 mm Mounting bracket DL5/ Cross bar Be aware of the length of the screws! To avoid damage of the lifting unit there must be at least 1 mm space between the ends of the 2 pcs. M8 screws for the mounting bracket and the surface of the lifting unit.
Mounting guidelines CBD6S (SMPS) The control box is to be fastened with 2 screws with a head diameter between ø 8 and ø 10 mm. With regard to the tension surface ø 10 mm is preferable due to a lower surface tension. See drawing appendix for placing of mounting holes and the space the CBD takes up.
Electric connection of the DL5/DL6 system The DESKLINE DL5/DL6 system is to be connected as shown on figure 4. Each DL5/DL6 is to be connected to the sockets on ® the control box by means of the motor cables, which have a 6-pin plug in each end. Finally, the mains cable is to be mounted and power switched on.
Initialisation of the DESKLINE DL5/DL6 parallel systems ® The DESKLINE system is intialised by pressing the down button once or twice and holding it down until DL5/DL6 runs into end stop, it will then automatically run approx. 3 mm out again and hereafter slowly run in again. Only release the down button when the movement has stopped completely.
Anti-Collision The function (Anti-Collision) is an option for the standard CBD6S (SMPS) control box. A system with Anti-Collision can limit material damages on a desk if a collision with a solid object should occur. Enabling the anti-collision To enable the Anti-Collision function a little plug called a dongle must be mounted in one of the 2 control ports. The function is only active when the dongle is mounted.
PIEZO™ description (optional) For optimised safety against squeezing and blocking on a desk, LINAK has developed DL6 columns with an integrated sensor, called PIEZO. The option minimises the risk of damage to a desk caused by squeezing or blocking of obstacles in up and down direction.
Accessories Please contact your nearest LINAK contract, distributor or subsidiary. Repairs Systems should only be repaired by an authorised LINAK service centre or engineer. Systems to be repaired under warranty must be sent to an authorised LINAK service centre. Warning! By unauthorised opening of the system there is a risk that it may malfunction at a later date.
Disposal of LINAK product As LINAK customers often ask us how our products can be disposed or scrapped we have prepared this guide that enables a classification to different waste fractions for recycling or combustion. Guide We recommend our products to be disassembled as much as possible and divided into different waste groups for recycling or combustion.
DECLARATION OF CONFORMITY LINAK A/S Smedevænget 8 DK - 6430 Nordborg hereby declares that LINAK Actuator System composed of: Control Box(s) CBD6SP00020A-309 CBD6S*000*0A-709 (The ‘*’ in the product description can either be a character or a number, thereby defining the variation of the product)
Page 30
LINAK APPLICATION POLICY The purpose of the application policy is to define areas of responsibilities in relation to applying a LINAK product defined as hardware, software, technical advice, etc. related to an existing or a new customer application. LINAK products, as defined above, are applicable for a wide range of applications within the Medical, Furniture, Desk and Industry areas.
While LINAK uses its best efforts to fulfil orders, LINAK cannot, for the same reasons as mentioned above, guarantee the availability of any particular product. Therefore, LINAK reserves the right to discontinue the sale of any product displayed on its website or listed in its catalogues or other written material drawn up by LINAK.