How to program the Auto Dialer
(If no key is pressed for 30 seconds, the Dialer will automatically exit the programming mode)
IMPORTANT: THE DIALER MUST BE IN THE OFF MODE FOR ALL PROGRAMMING.
SINCE THE DIALER WILL AUTOMATICALLY TURN ITSELF ON WHEN POWER IS FIRST CONNECTED OR
RECONNECTED, YOU NEED TO TURN THE DIALER OFF (ENTER CODE, DEFAULT 1234 AND THEN
PRESS EXIT KEY) BEFORE YOU CAN START PROGRAMMING AS BELOW.
Programming Sections:
1. Select Audible or Silent Alarm on trigger (Default – Silent Alarm)
2. Duration of Audible Alarm on trigger (Default – 3 Minutes)
3. Add or Delete Phone Numbers that are dialed out on trigger (Default – Memory empty)
4. Select a Delay between Trigger and Dial out (Default – No delay, instant dial out)
5. Select a Delay between the Dialer being turned on/armed and becoming active (Default – No delay)
6. Assign the 9 dial out Tel no's to trigger 1 and/or 2 ( Default – All Tel no's assigned to both trigger 1 & 2)
7. Select an Audible Arm Delay sound (Default – No sound)
Record.
Record the two voice messages
Play.
Play back the two voice messages
Password. Change the Default Password of 1234
NOTE: Only Programming Section 3, plus the Record, Play and Password Sections are essential to
programme. For most applications, the other sections can be left in their default settings.
Programming Section 6 can also be left in its default setting (activation of either trigger will mean ALL
telephone numbers that have been programmed into the dialer are dialed) unless you need to send
the Trigger 1 message to different phone numbers than those for Trigger 2.
NOTE: You must record at least One Voice Message and programme at least One Telephone number
into section 6 for the Dialer to work.