Power Supply Specifications
Item
Input power supply voltage
Power consumption
Connector Conversion Box only
Inrush current
Permissible instantaneous power failure time
Applicable GOTs
Abbreviations
GOT 2000
GT25 Handy GOT
GT16 Handy GOT
GOT 1000
GT14 Handy GOT
Internal Relay Contact Specifications
Item
Contact rating
Operation switch
10mA/24VDC
Each contact coordinates the operation switch status of Pressed (close)/Not pressed (open).
SW1 to SW6
(resistance load only)
When the external cable is not connected, contacts are always open regardless of the switch status.
Each contact coordinates the emergency stop switch status of Pushed (open)/Return (close). When the external cable is not
connected, contacts are always open regardless of the emergency stop switch status. Causing a short circuit of the ESB
terminal which is close to the ESA terminal by a short pin (prepared by user) enables to set each contact in the close status
even if the external connection cable is not connected.
1A/24VDC
Emergency stop
→GOT2000 Series User's Manual(Hardware), GT16 Handy GOT User's Manual, GT14 Handy GOT User's Manual
(resistance load)
switch
When using the short-circuited ESB terminal which is close to the ESA terminal
0.3A/24VDC
ES1A to ES3A
 Contacts are normally operated in the close status. When pushing the emergency stop switch, the contacts become open.
(induction load)
 In the following situations, contacts are closed regardless of the status of the emergency stop switch and the external cable.
- When GT16H-CNB-42S is turned OFF.
- When GT16H-CNB-42S is not supplied with the power supply (DC24V).
1A/24VDC
Grip switch
(resistance load)
Each contact coordinates the grip switch status of Pressed (close)/Not pressed (open).
DSW1, DSW2
0.3A/24VDC
When the external cable is not connected, contacts are always open regardless of the grip switch status.
(induction load)
Each contact coordinates the position of the keylock switch.
Keylock switch
1A/24VDC
(2-position switch)
(resistance load)
 When the key is on the left: KSW1 and KSWC are short-circuited.
KSWC, KSW1,
0.3A/24VDC
 When the key is on the right: KSW2 and KSWC are short-circuited.
KSW2
(induction load)
When the external cable is not connected, contacts are always open regardless of the keylock switch.
*1 The system may not match the safety standards. Before using the system, please check the safety standards which are required.
3. Part Names and External Dimensions
The name and the external dimensions of each part of the Connector Conversion
Box are described below.
External cable
Terminal block
connected
cover opened
56 (2.21")
55 (2.17")
110 (4.34")
2)
3)
4)
8)
15)
13)
10)
11)
about
65 (2.56")*
1)
16)
6) 7)
5)
about 130 (5.12")*
12)
*Space required for connecting the cable
Unit: mm (inch)
Weight: about 0.5kg
No.
Name
Specifications
Connector for Handy GOT
Connects a Handy GOT through an external
1)
(42-pin, female)
connection cable.
Supplies the power to the Handy GOT.
When this switch is set to ON, the power is
2)
Power switch
supplied. Turn off the power when attaching
or detaching the Handy GOT.
Lit in green: Power is correctly supplied. Not
3)
POWER LED
lit: Power is not supplied.
Used when mounting the panel. For M4
4)
Hole for the panel installation
screw, depth 6mm
5)
Packing attachment chase
Used when mounting the panel.
Specifications
24VDC (+10% -15%)
13.7W or less (570mA/24VDC) (When including the consumption current of Handy GOT)
2.2W (90mA/24V) (When excluding the consumption current of Handy GOT)
25A or less (at max. load), 2ms
Within 5ms
Model name
GT2506HS-VTBD, GT2505HS-VTBD
GT1655HS-VTBD
GT145□HS-Q□BDE
Specifications
*1
No.
Name
Used for fixing the Connector Conversion
6)
Hook for DIN rail
Box when mounting DIN rail (35mm).
Used for fixing on the board, etc. For M4
7)
Hole for the screw installation
screw
Connects the GT16H-CNB-42S, the 24VDC
14)
p o w e r s u pp l y o f H an d y G O T a n d t he
8)
Terminal block 1
emergency stop switch (ES-1 to 3) with M3
terminal screw and the cover.
Connects the operation switch of the Handy
GOT (SW1 to 6), the grip switch (DSW-1, 2)
9)
Terminal block 2
and the keylock switch (KSW-1, 2) with M3
terminal and the cover.
External connection device
9)
Connects to the external connection device
10)
communication connector
via a GOT2000/GOT1000 series cable.
(RS-232: D-Sub, 9-pin, male)
R S - 4 2 2 / 4 8 5 c o n n e c t o r a n d R S - 2 3 2
connector cannot be used at the same time.
External connection device
T h e s e c o n n e c t o r s c a n n o t b e u s e d i n
communication connector
11)
combination with GT2505HS-VTBD and
(RS-422/485: D-Sub, 9-pin,
GT145□HS-Q□BDE.
female)
External connection device
Connects the external connection device via
12)
communication connector
Ethernet with using a LAN cable.
(Ethernet: RJ-45 module jack)
13)
Rotary switch (U)
Sets the ID number of GT16-CNB-42S.
Sets one ID number with using both rotary
14)
Rotary switch (L)
switches (U) and (L).
Enables the recognition function of ID
number (ON=Valid, OFF=Invalid).
I D n u m b e r v a l i d / i n v a l i d
15)
When connecting the external connection
selection switch
device with using 10) and 11), set OFF
(invalid).
Used for fixing the flange when using the
16)
Hole for the flange installation
connector conversion adapter.
4. Installation
The Connector Conversion Box can be installed on the panel face directly or on the DIN rail.
4.1 Mounting on the panel face
(When setting the connector for Handy GOT connection and the power supply switch on the panel surface)
1) Direct mounting on the panel face
Drill a mounting slot of the following size on the panel face.
77±0.5 (3.04"±0.02")
4-R3 max (Panel opening)
3) Mounting on the panel face
Fit the Connector Conversion Box from the back side of the panel face, and fix it with four M4 screws (prepared by user).
In the Connector Conversion Box, thread of M4, 6mm (0.23") in depth is cut in each mounting hole. Prepare four M4 mounting screws separately while considering the
thickness of the panel face. (Tightening torque: 0.69 to 0.88 N•m)
Make sure that interfering objects are not located within 65mm (2.56") from the rear face so that the connector of a PLC cable is not hindered.
To wire the terminal block, keep a space of 25mm (0.98") or more on both sides of the Connector Conversion Box.
4.2 Mounting on the panel face (When installing the Connector Conversion Box on the panel surface)
1) Mounting on the panel face
Install the Connector Conversion Box on the panel face (mounting surface). Drill screw holes on the panel face as follows. Tighten the mounting screw with the specified
torque. Tightening screws too much may cause damage. (Tightening torque: 0.69 to 0.88 N•m)
Specifications
4.3 Installed on the DIN rail
Install the Connector Conversion Box on the DIN rail
with using its DIN rail hook.
(Applicable DIN rail DIN46277 (width: 35mm (1.37"))
The clearance between screws for install the DIN
rail should be 150mm (5.9") or less.
1) Pull out the hook for
2) Adapt the upper side of
DIN rail.
the DIN rail installation
slot to the DIN rail.
2) Installation of the packing
Install the accessory packing to the packing attachment chase of the
Connector Conversion Box. Be sure to install the packing.
Drill 4- 5±0.5 (0.2"±0.02")
Panel cut area
61+1,-0 (2.41"+0.04",-0)
Unit: mm (inch)
(Panel opening)
65 (2.56")
43 (1.7") 6 (0.24")
M4 screw and nut
× 4 sets
This manual confers no industrial property rights or any rights of any other
(prepared by user)
kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation
cannot be held responsible for any problems involving industrial property rights
4- 4.5 (0.18")
which may occur as a result of using the contents noted in this manual.
Unit: mm (inch)
Warranty
Exclusion of loss in opportunity and secondary loss from warranty liability
Regardless of the gratis warranty term, Mitsubishi shall not be liable for
compensation to:
DIN rail depth
(1) Damages caused by any cause found not to be the responsibility of
more than 10mm (0.4"inch)
Mitsubishi.
(2) Loss in opportunity, lost profits incurred to the user by Failures of Mitsubishi
products.
(3) Special damages and secondary damages whether foreseeable or not,
compensation for accidents, and compensation for damages to products
other than Mitsubishi products.
3) Lock the hook for DIN rail
(4) Replacement by the user, maintenance of on-site equipment, start-up test run
while forcing the product on
and other tasks.
the DIN rail.
When installing the DIN rail,
please fix the cables.
Otherwise, the hook for DIN
This product has been manufactured as a general-purpose part for general
rail and other parts may be
industries, and has not been designed or manufactured to be incorporated in
damaged by the cable load.
a device or system used in purposes related to human life.
Before using the product for special purposes such as nuclear power, electric
power, aerospace, medicine or passenger movement vehicles, consult with
Mitsubishi Electric.
This product has been manufactured under strict quality control. However
when installing the product where major accidents or losses could occur if the
product fails, install appropriate backup or failsafe functions in the system.
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
Elevation view
Packing attachment chase
25 (0.99")
25 (0.99")
Unit: mm (inch)
For safe use