Download Print this page

Mitsubishi Electric GT16H-CNB-42S User Manual page 3

Connector conversion box

Advertisement

JY997D40401H
Side
JAPANESE
A
Side
ENGLISH
B
CONNECTOR CONVERSION BOX
GT16H-CNB-42S
User's Manual
Manual Number
JY997D40401H
Date
April 2018
This manual describes the part names, dimensions, mounting, and specifications
of the product. Before use, read this manual and manuals of relevant products
fully to acquire proficiency in handling and operating the product. Make sure to
learn all the product information, safety information, and precautions.
And, store this manual in a safe place so that you can take it out and read it
whenever necessary. Always forward it to the end user.
Registration
Ethernet is a registered trademark of Xerox Corporation in the United States.
MODBUS is a trademark of Schneider Electric SA. The company name and the
product name to be described in this manual are the registered trademarks or
trademarks of each company.
Effective April 2018
Specifications are subject to change without notice.
2010 MITSUBISHI ELECTRIC CORPORATION
Safety Precaution
(Read these precautions before using.)
Before using this product, please read this manual and the relevant manuals
introduced in this manual carefully and pay full attention to safety to handle the
product correctly.
The precautions given in this manual are concerned with this product.
In this manual, the safety precautions are ranked as
and
Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury or
physical damage.
Depending on circumstances, procedures indicated by
linked to serious results.
In any case, it is important to follow the directions for usage.
DESIGN PRECAUTIONS
 Some failures of the GOT or cable may keep the outputs on or off.
An external monitoring circuit should be provided to check for output signals
which may lead to a serious accident.
Not doing so can cause an accident due to false output or malfunction.
 If a communication fault (including cable disconnection) occurs during
monitoring on the GOT, communication between the GOT and PLC CPU is
suspended and the GOT becomes inoperative.
A system where the GOT is used should be configured to perform any
significant operation to the system by using the switches of a device other
than the GOT on the assumption that a GOT communication fault will occur.
Not doing so can cause an accident due to false output or malfunction.
 Do not use the GOT as the warning device that may cause a serious
accident. An independent and redundant hardware or mechanical interlock is
required to configure the device that displays and outputs serious warning.
Failure to observe this instruction may result in an accident due to incorrect
output or malfunction.
DESIGN PRECAUTIONS
 Do not bundle the control and communication cables with main-circuit, power
or other wiring. Run the above cables separately from such wiring and keep
them a minimum of 100mm (3.94in.) apart.Not doing so noise can cause a
malfunction.
Power Supply Specifications
Item
Input power supply voltage
Power consumption
Connector Conversion Box only
Inrush current
Permissible instantaneous power failure time
Applicable GOTs
Abbreviations
GOT 2000
GT25 Handy GOT
GT16 Handy GOT
GOT 1000
GT14 Handy GOT
Internal Relay Contact Specifications
Item
Contact rating
Operation switch
10mA/24VDC
Each contact coordinates the operation switch status of Pressed (close)/Not pressed (open).
SW1 to SW6
(resistance load only)
When the external cable is not connected, contacts are always open regardless of the switch status.
Each contact coordinates the emergency stop switch status of Pushed (open)/Return (close). When the external cable is not
connected, contacts are always open regardless of the emergency stop switch status. Causing a short circuit of the ESB
terminal which is close to the ESA terminal by a short pin (prepared by user) enables to set each contact in the close status
even if the external connection cable is not connected.
1A/24VDC
Emergency stop
→GOT2000 Series User's Manual(Hardware), GT16 Handy GOT User's Manual, GT14 Handy GOT User's Manual
(resistance load)
switch
When using the short-circuited ESB terminal which is close to the ESA terminal
0.3A/24VDC
ES1A to ES3A
 Contacts are normally operated in the close status. When pushing the emergency stop switch, the contacts become open.
(induction load)
 In the following situations, contacts are closed regardless of the status of the emergency stop switch and the external cable.
- When GT16H-CNB-42S is turned OFF.
- When GT16H-CNB-42S is not supplied with the power supply (DC24V).
1A/24VDC
Grip switch
(resistance load)
Each contact coordinates the grip switch status of Pressed (close)/Not pressed (open).
DSW1, DSW2
0.3A/24VDC
When the external cable is not connected, contacts are always open regardless of the grip switch status.
(induction load)
Each contact coordinates the position of the keylock switch.
Keylock switch
1A/24VDC
 When the key is on the left: KSW1 and KSWC are short-circuited.
(2-position switch)
(resistance load)
KSWC, KSW1,
0.3A/24VDC
 When the key is on the right: KSW2 and KSWC are short-circuited.
KSW2
(induction load)
When the external cable is not connected, contacts are always open regardless of the keylock switch.
*1 The system may not match the safety standards. Before using the system, please check the safety standards which are required.
3. Part Names and External Dimensions
The name and the external dimensions of each part of the Connector Conversion
Box are described below.
External cable
Terminal block
connected
cover opened
56 (2.21")
55 (2.17")
110 (4.34")
2)
3)
4)
8)
15)
13)
10)
11)
about
65 (2.56")*
1)
16)
6) 7)
5)
about 130 (5.12")*
12)
*Space required for connecting the cable
Unit: mm (inch)
Weight: about 0.5kg
No.
Name
Specifications
Connector for Handy GOT
Connects a Handy GOT through an external
1)
(42-pin, female)
connection cable.
Supplies the power to the Handy GOT.
When this switch is set to ON, the power is
2)
Power switch
supplied. Turn off the power when attaching
or detaching the Handy GOT.
Lit in green: Power is correctly supplied. Not
3)
POWER LED
lit: Power is not supplied.
Used when mounting the panel. For M4
4)
Hole for the panel installation
screw, depth 6mm
5)
Packing attachment chase
Used when mounting the panel.
Side
B
MOUNTING PRECAUTIONS
 Make sure to turn off the Connector Conversion Box's power before attaching or
detaching it to/from the GOT.
Failure to do so may cause unit failure or malfunctions.
MOUNTING PRECAUTIONS
 Use the Connector Conversion Box within the generic environment specifications
described in this manual. If the product is used in such conditions, electric shock,
fire, malfunctions, deterioration or damage may occur.
WIRING PRECAUTIONS
 Be sure to shut off all phases of the external power supply used by the system
before wiring. Failure to do so may result in an electric shock, product damage or
malfunctions.
 Please make sure to ground FG terminal of the Connector Conversion Box power
supply section by applying 100 or less which is used exclusively for the GOT. Not
doing so may cause an electric shock or malfunction.
 Correctly wire the Connector Conversion Box power supply section after
confirming the rated voltage and terminal arrangement of the GOT. Not doing so
can cause a fire or failure.
 Exercise care to avoid foreign matter such as chips and wire offcuts entering the
GOT. Not doing so can cause a fire, failure or malfunction.
WIRING PRECAUTIONS
 Plug the communication cable into the connector of the connected unit and
tighten the mounting and terminal screws in the specified torque range.
Undertightening can cause a short circuit or malfunction. Overtightening can
cause a short circuit or malfunction due to the damage of the screws or unit.
TEST OPERATION
PRECAUTIONS
 Before performing the test operations of the user creation monitor screen (such as
turning ON or OFF bit device, changing the word device current value, changing
.
the settings or current values of the timer or counter, and changing the buffer
memory current value), read through the manual carefully and make yourself
familiar with the operation method. During test operation, never change the data
of the devices which are used to perform significant operation for the system.
False output or malfunction can cause an accident.
STARTUP/MAINTENANCE
PRECAUTIONS
may also be
 When power is on, do not touch the terminals.
Doing so can cause an electric shock or malfunction.
 Before starting cleaning or terminal screw retightening, always switch off the
power externally in all phases. Not switching the power off in all phases can cause
a unit failure or malfunction. Undertightening can cause a short circuit or
malfunction. Overtightening can cause a short circuit or malfunction due to the
damage of the screws or unit.
STARTUP/MAINTENANCE
PRECAUTIONS
 Do not disassemble or modify the unit.
Doing so can cause a failure, malfunction, injury or fire.
 Do not touch the conductive and electronic parts of the unit directly.
Doing so can cause a unit malfunction or failure.
 The cables connected to the unit must be run in ducts or clamped.
Not doing so can cause the unit or cable to be damaged due to the dangling,
motion or accidental pulling of the cables or can cause a malfunction due to a
cable connection fault.
 When unplugging the cable connected to the unit, do not hold and pull the cable
portion. Doing so can cause the unit or cable to be damaged or can cause a
malfunction due to a cable connection fault.
DISPOSAL PRECAUTIONS
 When disposing of the product, handle it as industrial waste.
TRANSPORTATION
PRECAUTIONS
 The Connector Conversion Box is a precision instrument. During transportation,
avoid impacts larger than those specified in this manual. Failure to do so may
cause failures in the unit. After transportation, verify the operations of the unit.
Specifications
24VDC (+10% -15%)
13.7W or less (570mA/24VDC) (When including the consumption current of Handy GOT)
2.2W (90mA/24V) (When excluding the consumption current of Handy GOT)
25A or less (at max. load), 2ms
Within 5ms
Model name
GT2506HS-VTBD, GT2505HS-VTBD
GT1655HS-VTBD
GT145□HS-Q□BDE
Specifications
*1
No.
Name
Used for fixing the Connector Conversion
6)
Hook for DIN rail
Box when mounting DIN rail (35mm).
Used for fixing on the board, etc. For M4
7)
Hole for the screw installation
screw
Connects the GT16H-CNB-42S, the 24VDC
14)
p o w e r s u pp l y o f H an d y G O T a n d t he
8)
Terminal block 1
emergency stop switch (ES-1 to 3) with M3
terminal screw and the cover.
Connects the operation switch of the Handy
GOT (SW1 to 6), the grip switch (DSW-1, 2)
9)
Terminal block 2
and the keylock switch (KSW-1, 2) with M3
terminal and the cover.
External connection device
9)
Connects to the external connection device
10)
communication connector
via a GOT2000/GOT1000 series cable.
(RS-232: D-Sub, 9-pin, male)
R S - 4 2 2 / 4 8 5 c o n n e c t o r a n d R S - 2 3 2
connector cannot be used at the same time.
External connection device
T h e s e c o n n e c t o r s c a n n o t b e u s e d i n
communication connector
11)
combination with GT2505HS-VTBD and
(RS-422/485: D-Sub, 9-pin,
GT145□HS-Q□BDE.
female)
External connection device
Connects the external connection device via
12)
communication connector
Ethernet with using a LAN cable.
(Ethernet: RJ-45 module jack)
13)
Rotary switch (U)
Sets the ID number of GT16-CNB-42S.
Sets one ID number with using both rotary
14)
Rotary switch (L)
switches (U) and (L).
Enables the recognition function of ID
number (ON=Valid, OFF=Invalid).
I D n u m b e r v a l i d / i n v a l i d
15)
When connecting the external connection
selection switch
device with using 10) and 11), set OFF
(invalid).
Used for fixing the flange when using the
16)
Hole for the flange installation
connector conversion adapter.
Certification of UL, cUL standards
UL, cUL Standards are recognized in use by the following combination.
 GT2506HS-VTBD
 GT2505HS-VTBD
 GT1665HS-VTBD (Hardware version F or later)
 GT1455HS-QTBDE (Hardware version B or later)
 GT1450HS-QMBDE (Hardware version B or later)
 GT16H-CNB-42S (Hardware version D or later)
 External cable (GT16H-C30-42P, GT16H-C60-42P, GT16H-C100-42P)
 External cable (GT14H-C30-42P, GT14H-C60-42P, GT14H-C100-42P)
*1 Version B or later
General notes on power supply
This equipment must be supplied by a UL Listed or Recognized 24 V dc rated
power supply and UL Listed or Recognized fuse rated not higher than 4A, or a UL
Listed Class 2 power supply.
Compliance with EC directive (CE Marking)
This note does not guarantee that an entire mechanical module produced in
accordance with the contents of this note will comply with the following standards.
Compliance to EMC directive for the entire mechanical module should be checked by
the user/manufacturer. For more details please contact the local Mitsubishi Electric
sales site.
Attention
 This product is designed for use in industrial applications.
Requirement for Compliance with EMC directive
The following products have shown compliance through direct testing (to the
identified standards) and design analysis (forming a technical construction file) to the
European Directive for Electromagnetic Compatibility (2004/108/EC) when used as
directed by the appropriate documentation.
Type: Programmable Controller (Open Type Equipment)
Standard
EMI
EN61131-2 : 2007
P r o g r a m m a b l e
controllers- Equipment,
EMS
requirement and tests
For more details please contact the local Mitsubishi Electric sales site.
Notes for compliance to EMC regulation
1) General notes on the control panel
Make sure to combine the GT16 Handy GOT with the Connector Conversion
Box to comply with the EMC directive. The Connector Conversion Box is an
open type device (device installed to another device) and must be installed in a
conductive control panel.
2) General notes on the use of communication cables
 External cable (GT16H-C30-42P, GT16H-C60-42P, GT16H-C100-42P)
 Direct connection cable
Existing Cables
The cable need to be independently tested by the user to
GT01-C30R4-8P
demonstrate EMC compatibility when they are used with
GT11H-C30R2-6P
the GOT, the PLC of MELSEC-Q series, MELSEC-L series,
MELSEC-QnA, MELSEC-A series and MELSEC-FX series.
 Ethernet connection cable (Shielded twisted pair cable (STP))
 PLC (manufactured by other company), microcomputer, temperature
controller, inverter, servo amplifier, CNC, MODBUS(R)/RTU or MODBUS(R)/
TCP connection
Produce the cable (RS-232 cable, RS-422 / 485 cable) for connecting the GOT
to a controller with reference to the following manual.
 GOT2000/GOT1000 Series Connection Manual for GT Works3 and a
controller used
3) General notes on Power supply
The Connector Conversion Box requires an
additional ferrite filter to be attached to the
24V DC power supply cables. The filter
should be attached in a similar manner as
shown in the figure opposite, i.e. the power
c a b l e s a r e w r a p p e d a r o u n d t h e f i l t e r.
However, as with all EMC situations the more
correctly applied precautions the better the
systems Electro-magnetic Compatibility. The
ferrite recommended is a TDK ZCAT3035-
1330 or similar. The ferrite should be placed
as near to the 24V DC terminals of the
Connector Conversion Box as possible (which
should be within 75mm of the GOT terminal).
Associated Manuals
The following manuals are relevant to this product. When these loose manuals are
required, please consult with our local distributor.
4. Installation
The Connector Conversion Box can be installed on the panel face directly or on the DIN rail.
4.1 Mounting on the panel face
(When setting the connector for Handy GOT connection and the power supply switch on the panel surface)
1) Direct mounting on the panel face
Drill a mounting slot of the following size on the panel face.
4-R3 max (Panel opening)
3) Mounting on the panel face
Fit the Connector Conversion Box from the back side of the panel face, and fix it with four M4 screws (prepared by user).
In the Connector Conversion Box, thread of M4, 6mm (0.23") in depth is cut in each mounting hole. Prepare four M4 mounting screws separately while considering the
thickness of the panel face. (Tightening torque: 0.69 to 0.88 N•m)
Make sure that interfering objects are not located within 65mm (2.56") from the rear face so that the connector of a PLC cable is not hindered.
To wire the terminal block, keep a space of 25mm (0.98") or more on both sides of the Connector Conversion Box.
4.2 Mounting on the panel face (When installing the Connector Conversion Box on the panel surface)
1) Mounting on the panel face
Install the Connector Conversion Box on the panel face (mounting surface). Drill screw holes on the panel face as follows. Tighten the mounting screw with the specified
torque. Tightening screws too much may cause damage. (Tightening torque: 0.69 to 0.88 N•m)
Specifications
4.3 Installed on the DIN rail
Install the Connector Conversion Box on the DIN rail
with using its DIN rail hook.
(Applicable DIN rail DIN46277 (width: 35mm (1.37"))
The clearance between screws for install the DIN
rail should be 150mm (5.9") or less.
1) Pull out the hook for
2) Adapt the upper side of
DIN rail.
the DIN rail installation
slot to the DIN rail.
Manual name
GOT2000 Series
User's Manual
(Hardware)
GOT2000 Series
Handy GOT
*1
Connection Manual
For GT Works3
Version1
GT16 Handy GOT
User's Manual
(Hardware/Utility,
Connection) 1/2, 2/2
(sold separately)
GT14 Handy GOT
User's Manual
(Hardware/Utility,
Connection) 1/2, 2/2
(sold separately)
For details of a PLC to be connected, refer to the PLC user's manual respectively.
Referenced Standard: GB/T15969.2 (Requirement of Chinese standardized law)
Bundled Items
GT16H-CNB-42S Connector conversion box
Remark
Packing for panel installation
Compliance with all relevant aspects of the
standard. (Radiated Emissions)
Flange for GT10-9PT5S
Compliance with all relevant aspects of the
Screws for flange installation (M3×8)
standard. (ESD, RF electromagnetic field, EFTB,
Surge, RF conducted disturbances and Power
CONNECTOR CONVERSION BOX GT16H-CNB-42S User's
frequency magnetic field)
Manual (This manual)
1. Features
The Connector Conversion Box relays the GOT's external 42-pin connector to the
power supply/switch and the PLC's connector and terminal block, while enabling
users to operate the Handy GOT outside the enclosure.
User Made Cables
2. Specifications
General Specifications
Other specifications are the same as the Handy GOT main unit.
Item
Operating
ambient
temperature
Storage
ambient
Up to 75mm
temperature
(2.95inch)
Vibration
resistance
Operating
atmosphere
2) Installation of the packing
Install the accessory packing to the packing attachment chase of the
Connector Conversion Box. Be sure to install the packing.
Drill 4- 5±0.5 (0.2"±0.02")
77±0.5 (3.04"±0.02")
Panel cut area
61+1,-0 (2.41"+0.04",-0)
Unit: mm (inch)
(Panel opening)
65 (2.56")
43 (1.7") 6 (0.24")
M4 screw and nut
× 4 sets
This manual confers no industrial property rights or any rights of any other
(prepared by user)
kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation
4- 4.5 (0.18")
cannot be held responsible for any problems involving industrial property rights
which may occur as a result of using the contents noted in this manual.
Unit: mm (inch)
Warranty
Exclusion of loss in opportunity and secondary loss from warranty liability
Regardless of the gratis warranty term, Mitsubishi shall not be liable for
compensation to:
DIN rail depth
(1) Damages caused by any cause found not to be the responsibility of
more than 10mm (0.4"inch)
Mitsubishi.
(2) Loss in opportunity, lost profits incurred to the user by Failures of Mitsubishi
products.
(3) Special damages and secondary damages whether foreseeable or not,
compensation for accidents, and compensation for damages to products
other than Mitsubishi products.
3) Lock the hook for DIN rail
(4) Replacement by the user, maintenance of on-site equipment, start-up test run
while forcing the product on
and other tasks.
the DIN rail.
When installing the DIN rail,
please fix the cables.
Otherwise, the hook for DIN
This product has been manufactured as a general-purpose part for general
rail and other parts may be
industries, and has not been designed or manufactured to be incorporated in
damaged by the cable load.
a device or system used in purposes related to human life.
Before using the product for special purposes such as nuclear power, electric
power, aerospace, medicine or passenger movement vehicles, consult with
Mitsubishi Electric.
This product has been manufactured under strict quality control. However
when installing the product where major accidents or losses could occur if the
product fails, install appropriate backup or failsafe functions in the system.
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
Manual Number
Contents
(Model Code)
Describes the GOT hardware relevant
content such as part names, external
SH-081194ENG
dimensions, mounting, power supply
(1D7MJ5)
wiring, specifications, and introduction
to option devices
Describes system configurations of the
co nnection method applicable to
SH-081867ENG
GOT2000 Series Handy GOT and
(1D7MS9)
cable creation method
Describes the Handy GOT hardware-
relevant content such as part names,
JY997D41201
external dimensions, mounting, power
JY997D41202
supply wiring, specifications, and
(09R821)
introduction to option devices
Describes the Handy GOT hardware-
relevant content such as part names,
JY997D50201
external dimensions, mounting, power
JY997D50202
supply wiring, specifications, and
(09R825)
introduction to option devices
Bundled item
Quantity
1
1
1
2
1
Handy GOT
Control panel or
operation panel
GT16H-CNB-42S
Connector Conversion Box
PLC
External cable
GT16H-C□□□-42P
GT14H-C□□□-42P
(Option)
Specifications
0 to 55C
-20 to 70C
Half-
Sweep
Frequency Acceleration
amplitude
Count
 When
5 to 9Hz
--
1.75mm
10 times
installing
each in X, Y
DIN rail
and Z
9 to 150Hz
4.9m/s
2
--
directions
Must be free of lamp black, corrosive gas, flammable gas, or
excessive amount of electroconductive dust particles and must be no
direct sunlight. (Same as for saving)
Elevation view
Packing attachment chase
25 (0.99")
25 (0.99")
Unit: mm (inch)
For safe use

Advertisement

loading