Extraordinary Maintenance - Eden SOFT-ECM NC Installation, Operation And Maintenance Manual

Water cassette model
Table of Contents

Advertisement

water cassette
SOFT / SOFT-ECM

EXTRAORDINARY MAINTENANCE

ATTENTION!
Turn off the automatic circuit breaker before carrying out any cleaning
operations. Use a cloth dampened with lukewarm water (max 40°C)
and mild detergent to clean the cassette. Do not use solvents or harsh
detergents.
OPENING THE PANEL
1. Identify, on the grill, the "PULL" written and pull the panel downward, without
forcing the hinges that fasten it to the appliance (Pic. 30 - 30a)
2. Remove the "stop-filter" seal with a screwdriver. (Pic. 31).
3. Extract the filter pushing up the tab (Pic. 32).
IMPORTANT! Place again the "stop-filter" seal when the filter comes rein-
stalled on the unit.
Vers. 2015-3
FILTER CLEANING
The filter must be clean with vacuum cleaner and wash with lukewarm water
and mild detergent. Make sure the filters are dry before replacing them in the
appliance.
ATTENTION! Do not expose the filters to sunSOFT.
NB!
NEVER OPERATE THE CASSETTE WITHOUT THE AIR FILTERS!
END OF SEASON MAINTENANCE
Pic. 30
- Clean and replace the filters.
- On a sunny day leave the cassette running in fan mode for a few hours to allow
the inside of the unit to dry completely.
- Remove the plug or turn off the automatic circuit-breaker.
WHAT TO DO IF...
The unit does not go on? Check that...
Does it seem to heat or cool less than usual? Check that...
Pic. 30a
DISMANTLING THE APPLIANCE
This appliance is made to last for many years. Qualified personnel are needed
to dismantle it in all safety. The first operation to be carried out before disman-
tling the appliance is to disconnect it totally from the electricity supply.
Pic. 31
This appliance has been made using recyclable materials (copper, aluminium,
brass, plastic) assembled by screws and push-fits to make separation of the
parts easy.
Contact a firm specialised in differentiated waste disposal; it is the only way
to be certain of correct recycling and thereby contribute to protection of the
environment.
Pic. 32
19
INSTALLATION, OPERATION
AND MAINTENANCE MANUAL
1
2
3
4
...
that the mains supply is reaching the unit
...
that the plug is properly inserted
...
if the circuit breaker has tripped
...
if there been a failure in the mains supply
...
that the temperature has been set correctly
...
if a window or door has been opened
...
the filters for clogging
...
for obstacles that prevent the free circulation of air
...
if the cassette is exposed to direct sunSOFT
Pic. 33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Soft ncSoft rcSoft-ecm rc

Table of Contents