TH Series
Connections
Each connector panel has two Neutrik Speakon connectors wired in parallel with each other. The second connector allows use
of a short link lead to power another, parallel TH loudspeaker. The connectors are wired as follows:
Cable lengths
When connecting Blackline+ systems to an amplifier, it is recommended that the return resistance of the cable used is less than
one tenth of the nominal impedance of the system or systems in parallel. The table below gives an indication of the maximum
permissible cable runs for various conductor cross‐sectional areas.
Conductor CSA
1.0mm²
1.5mm²
2.0mm²
2.5mm²
4.0mm²
6.0mm²
Recommended controllers
Controllers must be used with the bi‐amplified THV and THH. Controllers must also be used when adding a subwoofer such as
an SX218 to a system as this very high power subwoofer does not include a passive low‐pass network.
DX0.5
The DX0.5 is a powerful 2in‐6out DSP based audio processing unit for live applications and fixed installations.
The unit is configurable in 5 basic modes (2 x stereo + sub, 3 x stereo, 2 x 2‐way + sub, 2 x 3‐way and 1 x 6‐way). Each input has
adjustable gain and delay. Each output consists of a high and low pass filter, 5 bands of parametric equalisation, limiter, delay
(adjustable in 2.6 μs steps), gain and polarity controls. A USB Port allows connection to a PC for desk‐top control using the
dedicated DX0.5 control application available free of charge from www.martin‐audio.com.
Please refer to the DX0.5 user guide for further information.
TH Series User Guide V1.0
USER GUIDE
4 ohms
11m
17m
22m
29m
44m
66m
Maximum Cable Run
8 ohms
22m
34m
44m
58m
88m
132m
16 ohms
44m
68m
88m
116m
176m
264m
11