Download Print this page

Botex DPX-620 Operation Manuals page 2

Advertisement

1. DMX output socket
Use to connect to DMX input socket of next unit for parallel control.
2. DMX input socket
Use to connect to DMX input signals.
3. ANALOG output (8-pin din socket)
4. ANALOG input (8-pin din socket)
5. Output wiring port (x5)
Use to connect to 6 channel output, 10A per channel max., Total 60A max.(
20A per channel max., Total 120A max. (
OPERATION
1. Please confirm power requirement is matched with that specified on this unit
2.Set up correct wire connections. (see connections diagram).
SINGLE PHASE CONNECTION
LOADING
E
N
CH6
CH5
CH4
CH3
CH2
CH1
LOADING
POWER INPUT:
OUTPUT:
10A per channel, Total 60A
POWER INPUT:
CHINA
OUTPUT:
20A per channel, Total 120A
THREE-PHASE CONNECTION
LOADING
E
N
CH6
CH5
CH4
CH3
CH2
CH1
LOADING
POWER INPUT:
OUTPUT:
10A per channel, Total 20A per phase
POWER INPUT:
CHINA
OUTPUT:
20A per channel, Total 40A per phase
CE
CHINA
)
N
N
N
N
L
AC 230V~50-60Hz
AC 220V~50-60Hz
N
N
N
L3
L2
L1
N
L3
L2
L1
AC 230V~50-60Hz
AC 220V~50-60Hz
3. Apply to required control signals.
4. Check for proper wire connections, turn power switch on.
5. Allow the system to connect available control signals at a time, the prevailing one should
control channel output. If PREHEAT control is set to maximum, channel dimmer level should
be 50 percent of setting maximum dimmer.
6. Receive DMX signals
.
Primarily, select initial channel to apply to DMX signals.
)
.
Set dipswitch 10 to ON, the system should receive only the first channel DMX signals
which synchronously control 6 channel output.
.
Set dipswitch 10 to OFF, the system should receive 6 channel DMX signals and control 6
channel output in sequence, how DMX indicator should turn on.
7. Appropriate initial channel DMX setting mode is refered to following table:
1
0
1
0
1
0
1
0
1
1
8. Turn the power switch off, adjust channel program setting, and then turn the power on.
9. Receive 0-10V power level signals.
This unit transmit received level signals to ANALOG output, output supply is +20V DC
600mA max.
WARNING:
1. This apparatus must be earthed
2. To prevent fire or electric shock hazard, do not expose this apparatus to rain
or moisture.
3. In case circuit breaker is cut off automatically, check corresponding channel
to find whether there is any malfunction.
4.To assure ventilation, do not block or stack goods near to openings.
5. Wait for at least 3 seconds to turn on your unit after you have turned off your unit.
2
3
4
5
6
7
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
8
9
Initial channel
0
0
0
0
0
1
0
0
2
0
0
3
0
0
4
1
0
255
0
1
256
0
1
257
1
1
511

Advertisement

loading