Redundancy; Figure 2-4 Gx2-Psdc10D-R Rear View - Motorola GX2-PSDC10D-R Installation And Operation Manual

Table of Contents

Advertisement

Overview
2-3
Figure 2-4 illustrates a rear view of the GX2-PSDC10D-R:
Figure 2-4
GX2-PSDC10D-R rear view

Redundancy

The unused compartment on the bottom of the GX2-HSG* can be used for redundant powering
with the purchase of a second power supply. For redundancy, it is possible to use two
GX2-PSDC10D-Rs (as shown in Figure 3-1), two GX2-PSAC10D-Rs, or any combination of
GX2-PS*10C or GX2-PS*10D-R power supplies. It is not possible to use one GX2-PSDC10B and
one GX2-PSDC10D-R power supply together for redundancy. If one power supply fails, the other
assumes the entire load.
GX2-PSDC10D-R Installation and Operation Manual