9.0 Diagnostics and Control

Remotely accessible, real-time diagnostic data and status information is available from the 922-MES. This
information can be used for real-time health monitoring and long-term trending of critical parameters for
predictive analysis.
Ethernet Diagnostics (Modbus TCP/IP and Telnet): The Ethernet interface provides full diagnostics and
control of the card. Diagnostics and status information are retrievable using Modbus TCP/IP and/or Telnet over
any Ethernet port (copper or SFP).
Configuration options include:
Ethernet port control registers (e.g. forcing speed/duplex, rate limiting, aging, broadcast protection,
port priority, virtual local area network (VLAN) configuration, etc.)
Field update of embedded firmware, and user-controlled switching between stored firmware versions.
Factory Serial Diagnostics (RS-232): The RS-232 serial interface provides basic read-only diagnostics
information via a non-isolated interface (J3). It is intended for factory bench testing and debugging purposes
only. See section 6.6 for details.
Diagnostics information and control provided by the card is shown in the table below.
Diagnostics Type
Ethernet Copper Ports
Ethernet SFP Ports
Redundancy Mode
Optical SFP
On-board Sensors
Network, Analog Data and
Board Serials
Notes:
Diagnostics data shown is for cards with uC DIAG FW version ≥0xA3 where  = Diagnostics capability available. Blank =
1.
Diagnostics capability not available.
Focal Technologies Corporation
A Moog Inc. Company

Table 9-1: Diagnostics Information

Description
Link speed status (10/100/1000M)
Link speed configuration (10/100/1000M)
Duplex mode
Autonegotiation state
Link speed (100/1000M)
Link speed configuration (100/1000M)
MRP Status (MRC/MRM SFPs only)
MRP configuration
RSTP Status (Copper ports only)
RSTP configuration
Optical Tx/Rx power levels, Tx bias current, voltage
and temperature
Serial number and wavelength
Board temperature
Humidity
ON time counter
OFF event counter
Network settings and configuration (IP address,
Subnet Mask, Gateway, DNS, DHCP)
Analog data (on-board voltage rails and board current)
Board serial information (including serial number, date
code, FW version, MAC address)