4.1 Factory Default Settings
The card is shipped from the factory with default configuration settings as shown below and are applicable to
MES core FW P/N 922-1008-50 and diagnostics microcontroller FW P/N: 922-1008-00. Settings type marked
as "software" mean that they can only be changed via a diagnostics link to the card. Settings type marked as
"hardware" mean that they can only be changed via hardware modifications on the board.
Table 4-2: Factory Default Card Configuration Settings (as-built FW 922-1008-00/50)
Name
Ethernet CU1-CU8 (Software)
Link Speed
10BASE-T /100BASE-TX / 1000BASE-T
Duplex Mode
Full-Duplex or Half-Duplex
Negotiation
Autonegotiation Enabled / Disabled
RSTP
All ports On / Off
Ethernet SFP1-SFP2 (Software)
Link Speed
100BASE-FX / 1000BASE-X
Duplex Mode
Full-Duplex
MRP: On / Off
MRP
Mode: MRC / MRM
Boot up (Hardware)
JP1
Factory Use Only
Open: Normal operation (Internal Flash)
JP2
Close: uC DIAG code reset (on power-up
load from Factory Flash)
JP3
Factory Use Only
JP4
Factory Use Only
Diagnostics – uC DIAG (Software)
IP address
Subnet
Network
Gateway
Primary DNS
Secondary DNS
Enable / Disable
DHCP
Timeout (1-10 min)
Format: Short (Normal) / Long
UDP Heartbeat
Interval (1-254)
Focal Technologies Corporation
A Moog Inc. Company
Parameter
Model 922-MES – User Manual
Default Setting
10BASE-T /100BASE-TX / 1000BASE-T
Full Duplex
Autonegotiation Enabled
On
1000BASE-X
Full Duplex
MRP On, MRC mode (client)
Open
Open
Shorted
Shorted
192.168.0.100*
255.255.255.0
192.168.0.254
194.25.2.129
194.25.2.130
Enable
5 min.
Short (Normal)
5 seconds
Document No. 922-0662-00, Rev 1.0
Page 4-2