Diagnostic Leds; Jumpers; Table 6-1: On-Board Diagnostic Leds; Table 6-2: Hardwire Jumper (As-Built) - Focal 922-MES User Manual

Managed ethernet switch
Table of Contents

Advertisement

6.2 Diagnostic LEDs

The table below describes the on-board diagnostic LEDs on the card. LEDs are intended for bench level
verification as typical status from installed equipment is accessed via Ethernet.

Table 6-1: On-Board Diagnostic LEDs

LED
LED Name
D2
SFP2 LOS
D3
SFP1 LOS
D5
POWER
D6
SFP1 LINK
D7
SFP1 ACTIVITY
D8
CU1 LINK
D9
CU1 ACTIVITY
D12
SFP2 LINK
D13
SFP2 ACTIVITY
D14
CU2 LINK
D15
CU2 ACTIVITY
D16
CU3 LINK
D17
CU3 ACTIVITY
D18
CU4 LINK
D19
CU4 ACTIVITY
D20
CU5 LINK
D21
CU5 ACTIVITY
D22
CU6 LINK
D23
CU6 ACTIVITY
D24
CU7 LINK
D25
CU7 ACTIVITY
D26
CU8 LINK
D27
CU8 ACTIVITY
Notes:
1. Green: ON Solid = No loss of optical signal (No LOS). OFF = Loss of optical signal (LOS)
2. Green: ON Solid = Board is ON. OFF = Board is OFF.
3. Yellow: ON Solid = Ethernet Link Up. OFF = No Ethernet Link
4. Green: ON Solid = Ethernet Link Up. Blinking = Ethernet TX/RX Activity. OFF = No Ethernet Link.

6.3 Jumpers

The table below describes the hardware jumpers on the card.
Jumper
Name
JP1
FACTORY USE
uC DIAG
JP2
CODE RESET
JP3
FACTORY USE
JP4
FACTORY USE
Focal Technologies Corporation
A Moog Inc. Company
Note
1
1
2
D5
3
D6
D7
4
D8
3
D9
4
D12
3
D13
4
D14
3
D15
4
D16
3
D17
4
D18
3
D19
4
D20
3
D21
4
D22
3
D23
4
D24
3
D25
4
D26
3
D27
4

Table 6-2: Hardwire Jumper (as-built)

OPEN: Default
This jumper is only checked by the software on power up.
OPEN (default): Diagnostics uC runs in normal operation.
SHORTED: Revert uC DIAG firmware to factory version.
SHORTED: Default
SHORTED: Default
Model 922-MES – User Manual
D2
D3
Note
Document No. 922-0662-00, Rev 1.0
Page 6-3

Advertisement

Table of Contents
loading

Table of Contents