Rain Bird ESP-RZXe Installation And Operation Manual page 11

Table of Contents

Advertisement

Locate the transformer wiring compartment in
the lower left corner of the controller unit. Use a
screwdriver to remove the cover and expose the
transformer connection wires.
RESET
C M
1
2
3
4
5
6
7
8
24VAC
SENS
ACCESSORY
REMOTE
CONNECT
120 VAC
Route the three external power source wires
through the conduit opening at the bottom of
the unit and into the wiring compartment.
b
l
NOTE: If necessary, remove the knock-out on the
bottom of the controller below the transformer
and attach a 1/2 inch conduit to the unit.
Using the provided wire nuts, connect the
external power source wires (two power and
one ground) to the transformer connection
wires inside the wiring compartment.
c
l
WARNING: Ground wire must be connected to
provide electrical surge protection.
RESET
C M
1
2
3
4
5
6
7
8
24VAC
SENS
ACCESSORY
REMOTE
RESET
C M
1
2
3
4
5
6
7
8
24VAC
SENS
ACCESSORY
REMOTE
Power Wiring Connections
120 VAC (US)
Black supply wire (hot)
to the black transformer
wire
White supply wire
(neutral) to the white
transformer wire
Green supply wire
(ground) to the green
transformer wire
Verify that all wiring connections are secure,
then replace the wiring compartment cover and
secure it with the screw.
c
l
WARNING: DO NOT turn on power until
you have completed and checked all wiring
connections.
b
l
NOTE: DO NOT use an outlet that is controlled
by a secondary ON/OFF light switch or GFI
outlet.
b
l
NOTE: This appliance is not intended for use
by persons (including children) with reduced
physical, sensory or mental capabilities, or lack
of experience and knowledge, unless they
have been given supervision or instruction
concerning use of the appliance by a person
responsible for their safety.
Children should be supervised to ensure that
they do not play with the appliance.
c
l
WARNING: If the supply cord of an outdoor
controller is damaged, it must be replaced by
a special cord or assembly available from the
manufacturer or its service agent.
If the supply cord of an indoor controller
is damaged, it must be replaced by the
manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
9
230 VAC
(International)
Black supply wire (hot)
to the black transformer
wire
Blue supply wire (neutral)
to the blue transformer
wire
Green-with-yellow-stripe
supply wire (ground) to
the green-with-yellow-
stripe transformer wire

Hide quick links: