Page 1
MONARCH INSTRUMENT Instruction Manual Nova-Strobe vbx Vibration Battery x Strobe Printed in the U.S.A. Copyright 2009 Monarch Instrument, all rights reserved 1071-4220-110R 0209...
15 Columbia Drive, Amherst NH 03031 USA exceed the environmental specifications stated. declares under Monarch’s sole responsibility that the product: Use of this product may induce an epileptic seizure in persons prone to this type of attack.
This product may be returnable to your distributor for recycling - contact the distributor for details. CA-4046-6 6 foot (1.8M) Accelerometer input cable, 1/8 inch (3.5mm) male phone plug to BNC with BNC union Monarch Instrument’s Limited Warranty applies.
Page 4
4.4 Tachometer Mode - External Input Required .... 11 General: Time Base Ultra Stable Crystal Oscillator 4.5 External Delay Modes (Phase Shifting) ....12 Display LCD display with 6 numeric 0.506 inch [12.85 mm] high 4.6 Lock Modes - Accelerometer Input Required ..12 digits and 5 alphanumeric 0.282 inch [7.17 mm] high digits 4.7 Power Up Features ............
9.0 SPECIFICATIONS 1.0 OVERVIEW Internal Mode: The Nova-Strobe vbx is a truly portable, battery-operated stroboscope Flash Range 30 - 50,000 FPM (Flashes Per Minute) that is suited for a wide range of industrial, institutional, and educational 0.004% of setting or ± last digit Flash Rate Accuracy applications, and is able to interface with several of the Vibration Data Flash Rate Resolution...
All applications suited to a general purpose, phase shifting When charging, the strobe will indicate CHRGE in the bottom right of the stroboscope (Nova-Strobe pbx) display. The recharger will fast charge the batteries for about 4-5 hours and then trickle charge the batteries. The Nova-Strobe vbx can also be used as a highly accurate, remote electronic digital tachometer for direct measurement of RPM/RPS (speed) without Allow the recharger to charge the batteries until the display shows...
Page 7
The enclosure contains control electronics to properly and safely charge the On Target Indicator for Tachometer Mode and Remote batteries. Never remove the batteries from the enclosure and attempt to Sensor in External Mode charge externally. Only use the recharger supplied (PSC-pbxU). - - - - - Indicates input frequency exceeds the limit of the stroboscope...
In Internal Mode, toggles between normal flash rate adjust CAUTION: Do NOT allow the reflector to contact the lamp. and “phase” delay adjust Reinstall the reflector and then position the front lens in place In External and Lock Modes, cycles through External only matching up the notches on the lens with the two small tabs on (no delay), Phase, Time and Auto (VRPM) the housing to prevent lens rotation (see Figure 4).
Page 9
The input and output are TTL compatible. See Figures 2 and 3 for To change the lamp: connector connection detail. Push apart the two tabs on the side of the reflector housing and remove the lens using a small screwdriver to help pry one tab and Common lift the lens.
NOTE: When using external sensors that are powered by the Nova- when using a delayed flash mode. The Nova-Strobe vbx has an “Input Blanking” Strobe vbx, e.g. Remote Optical Sensor (ROS-P), the sensor feature to allow it to ignore this false trigger. must be plugged in before the stroboscope is turned on, or Even with the Input Blanking, large delays cannot be obtained using an ROS the remote sensor may not be powered up.
For these tests the strobe light should be set on a tripod. A long cable Once the desired menu option is displayed, press the MENU button will be needed for the sensor. The sensor should be mounted on a again to select/save it. Press any other button to cancel selection. magnetic base.
In the Internal Mode the knob adjusts the flash rate. In the External to an area above any split line, to the bearing cap. Note the phase Input Mode an external signal is used to trigger the flash and the knob has angle at each of these locations.
Page 13
This section outlines the preparations and use of the strobe light in order the reading on the display to the maximum or minimum values allowed. to be assured the measurements you are making are correct. This feature is useful for checking harmonics in the internal flashing mode.
allow it to be placed at a reference location. It may also be noted that slight To store the current flash rate in a Preset (memory) location: adjustment of the Phase Angle control knob may be required before each Press the ALT FUNCTION button and then the MEMORY button. measurement, to assure that the reference location is repeated.
Connect the proper interface cable between the strobe and the data collector To stop flashing: or analyzer. See wiring diagram to build the cable. The Input (Up Arrow) Press the ALT FUNCTION button and then the TACH button. and Output (Down Arrow) jacks are located on the left side of the strobe. The TACH icon will be displayed.
Balancing and Phase Measurement To exit the Tachometer Mode: Press the ALT FUNCTION button and then the TACH button. The Nova-Strobe vbx contains an internally tuned filter that is incorporated The TACH icon will go away. in a phase shifting network, which allows the shaft reference mark to be directed at any convenient location on the machine while balancing or External Delay Modes (Phase Shifting) performing motion studies (phase measurement) along a machine’s casing...
Page 17
powered, usually by the external Vibration Analyzer, and must be mounted in place. Special cable assemblies are available for several commercially available Vibration Analyzers, or you may “steal” the accelerometer signal and feed it into the strobe input as detailed above. Stopped Image 1/4 times 1/2 times...
After the image has been locked and the Narrow or Wide Bandwidth has 5.0 APPLICATIONS been optimized for the speed and/or background noise on the sensor Using the Stroboscope to Measure RPM signal, the Phase knob can be used to adjust the phase of the output pulse (and image) - refer to the Phase Analysis section later in this manual for The primary use for a stroboscope is to stop motion for diagnostic adjusting the Phase Angle control.
Need help?