Monarch 315 Instruction Manual

Mini humidity temperature meter

Advertisement

MONARCH INSTRUMENT
Instruction Manual
Monarch 315
Mini Humidity Temperature Meter
15 Columbia Drive
Amherst, NH 03031-2334 USA
Phone: (603) 883-3390
Fax: (603) 886-3300
© Monarch Instrument 2002 all rights reserved
E-mail: support@monarchinstrument.com
1071-8041-310
Website: www.monarchinstrument.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 315 and is the answer not in the manual?

Questions and answers

Summary of Contents for Monarch 315

  • Page 1 MONARCH INSTRUMENT Instruction Manual Monarch 315 Mini Humidity Temperature Meter 15 Columbia Drive Amherst, NH 03031-2334 USA Phone: (603) 883-3390 Fax: (603) 886-3300 © Monarch Instrument 2002 all rights reserved E-mail: support@monarchinstrument.com 1071-8041-310 Website: www.monarchinstrument.com...
  • Page 2: Safeguards And Precautions

    HAS BEEN ADVISED OR MADE AWARE OF THE POSSIBILITY OF ANY SUCH LOSSES OR DAMAGES assistance, contact the sales organization from AND REGARDLESS OF WHETHER THE CLAIM IS BASED ON CONTRACT, TORT, STRICT LIABILITY, which you purchased the product or Monarch OR OTHER THEORY OF LIABILITY. Instrument directly.
  • Page 3: Declaration Of Conformity

    MODEL 315 HUMIDITY TEMPERATURE METER DECLARATION OF CONFORMITY Table of Contents Monarch Instrument Section Page Division of Monarch International Inc. 15 Columbia Drive, Amherst NH 03031 USA 1.0 Introduction ....................declares that the product: 2.0 Specifications ..................Name: Humidity Temperature Meter...
  • Page 4: Specifications

    MODEL 315 HUMIDITY TEMPERATURE METER MODEL 315 HUMIDITY TEMPERATURE METER 1.0 Introduction: Notes on Temperature and Humidity Calibrations: 1. During either calibration, pressing the button at any time will return This instrument is a digital Humidity / Temperature meter incorporating a the instrument to the normal operating mode, and no calibration data polymer capacitive humidity sensor and a semiconductor temperature sensor in will be changed.
  • Page 5 MODEL 315 HUMIDITY TEMPERATURE METER MODEL 315 HUMIDITY TEMPERATURE METER Humidity Calibration 3.0 Symbol Definition and Button Locations: 1. Turn the unit off. Press and hold the HOLD and °C/°F buttons. While these two buttons are pressed, turn the power on. Release all buttons Data Hold indication Relative indication and all the segments on the display will blink.
  • Page 6: Calibration Procedure

    MODEL 315 HUMIDITY TEMPERATURE METER MODEL 315 HUMIDITY TEMPERATURE METER 4.0 Operating Instructions: Auto Power Off By default, the instrument powers on in the ‘Auto Power Off’ mode and will Preparation for Measurement: automatically shut off 30 minutes after the last key operation. To measure ambient humidity and temperature, hold the instrument in the To disable this feature, press and hold the HOLD button and then power on environment of interest and allow sufficient time for the sensors to respond...

This manual is also suitable for:

308

Table of Contents