Dometic DTM04 Installation And Operational Manual

Dometic DTM04 Installation And Operational Manual

Tank monitor systems
Hide thumbs Also See for DTM04:

Advertisement

TANK MONITOR SYSTEMS
DTM04 TANK MONITOR
DTM08 TANK MONITOR
DTM12 TANK MONITOR
INSTALLATION AND OPERATION MANUAL
1

Advertisement

Table of Contents
loading

Summary of Contents for Dometic DTM04

  • Page 1 TANK MONITOR SYSTEMS DTM04 TANK MONITOR DTM08 TANK MONITOR DTM12 TANK MONITOR INSTALLATION AND OPERATION MANUAL...
  • Page 2: Safety Instructions

    DTM08 DTM12 Tank Monitor Systems Dometic Tank Monitor Systems permit remote sensing of liquid levels in black or gray waste water, or potable freshwater tanks. Three float switches, which activate a set of four lights, are installed in the desired tank. One float activates a “Full” light when the liquid is within 2 inches (51 mm) of the top inside surface of the tank.
  • Page 3: Specifications

    • Optional shut-down relay plugs into circuit board to shut down toilet system when gray or black water waste tank is full (DTM04 model only). • Only one level light on at a time to eliminate confusion and save battery power.
  • Page 4: Installation

    TANK MONITOR SYSTEMS INSTALLATION Adjustable Tank Probe Cap 1. The tank probe cap is designed for a 3-inch FPT opening. Order part number 230272 if tank is made of rigid material and is not a SeaLand holding tank. 2. Loosen compression nuts on adjustable probes and install the cap into the tank. Slide the #1 probe down until the float touches the bottom of the tank.
  • Page 5 9. Install the probe cap and, if applicable, secure the 5/8-inch vent hose to the vent fitting with a stainless steel hose clamp. Shut-down Relay (optional – applies to DTM04 only) CAUTION: VERIFY THAT RELAY IS CORRECT VOLTAGE FOR SYSTEM (12VDC requires P/N 600341292 and 24VDC requires P/N 600342490).
  • Page 6: Wiring Diagrams

    TANK MONITOR SYSTEMS WIRING DIAGRAMS DTM04 Tank Monitor System for Blackwater Waste Tank USE 18GA. OR LARGER STRANDED COPPER WIRE. DTM04 TANK MONITOR IF OPTIONAL “TANK FULL” SHUT-DOWN RELAY IS INSTALLED, PINS 10 AND 11 REQUIRE 14GA. OR LARGER STRANDED COPPER WIRE.
  • Page 7 Shut-down Relay with DTM04 Tank Monitor System USE 12 OR 14 GAUGE STRANDED COPPER WIRE ON PINS 10 AND 11. DTM04 TANK WITH RELAY INSTALLED AND DTM04 MODEL WIRED FOR A MONITOR with BLACKWATER TANK, THE “FULL” FLOAT SWITCH WILL SHUT shut-down relay OFF ELECTRICAL POWER TO THE TOILET SYSTEM.
  • Page 8: Manufacturer's One-Year Limited Warranty

    If this Dometic product is placed in commercial or business use, it will be warranted, to the original purchaser only, to be free of defects in material and workmanship for a period of ninety (90) days from the date of purchase.
  • Page 9 INSTALLATION TEMPLATE – MONITOR PANEL Use this template with Dometic Monitor Panel installation instructions on page 4.

This manual is also suitable for:

Dtm12Dtm08