1. Outline
The M3062PT-EPBM is an MCU board for replacing the emulation probe M3062PT-EPB for the M16C/62P.

2. Package Components

Package components
M3062PT-EPBM MCU board for replacing the M3062PT-EPB
M3062PT-EPBM User's Manual (this manual)
M3062PT-EPBM User's Manual (Japanese)
3. Replacing the MCU Board
Four screws
Figure 3.1 Replacing the MCU board
Notes on Handling This Product:
• Before you replace the MCU board, shut off the power, otherwise internal circuits may be damaged.
• Insert or pull out the MCU board vertically, otherwise the connectors may be damaged.
• After replacing the MCU board, be careful about the direction for connecting to the PC7501.
Note on This Product:
• For inquiries about the product or the contents of this manual, contact your local distributor.
PCA7501EPBA
M3062PT-EPBM
PCA7501EPBA
New M3062PT-EPBM
CAUTION
(1) Unscrew the four screws the emulation probe.
(2) Pull out the M3062PT-EPBM from the PCA7501EPBA
vertically, otherwise the connectors may be damaged.
(3) Attach connectors J1 and J2 of the new M3062PT-EPBM
to connectors J4 and J3 of the PCA7501EPBA,
respectively.
(4) Tighten the four screws in an even, crisscross pattern to
secure the new M3062PT-EPBM.
(5) After replacing the board, perform the self-check to make
sure that it is installed properly.
( 2 / 2 )
1 piece
1 piece
1 piece